When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Flow table test - Wikipedia

    en.wikipedia.org/wiki/Flow_table_test

    The flow table test or slump-flow test is a method to determine consistency of fresh concrete. Flow table test is also used to identify transportable moisture limit of solid bulk cargoes. [ 1 ] It is used primarily for assessing concrete that is too fluid (workable) to be measured using the slump test , because the concrete will not retain its ...

  3. Concrete slump test - Wikipedia

    en.wikipedia.org/wiki/Concrete_slump_test

    The test is carried out using a metal mould in the shape of a conical frustum known as a slump cone or Abrams cone, that is open at both ends and has attached handles.The tool typically has an internal diameter of 100 millimetres (3.9 in) at the top and of 200 millimetres (7.9 in) at the bottom with a height of 305 millimetres (12.0 in).The cone is placed on a hard non-absorbent surface.

  4. Slump test - Wikipedia

    en.wikipedia.org/wiki/Slump_test

    Patient should be sitting on the edge of the table while the examiner is by the side of the patient. [citation needed] The slump test consists of several different steps: [citation needed] First, the patient slumps forward, rounding the shoulders [1] so the examiner will then apply pressure to the trunk flexion.

  5. Concrete - Wikipedia

    en.wikipedia.org/wiki/Concrete

    Workability can be measured by the concrete slump test, a simple measure of the plasticity of a fresh batch of concrete following the ASTM C 143 or EN 12350-2 test standards. Slump is normally measured by filling an "Abrams cone" with a sample from a fresh batch of concrete. The cone is placed with the wide end down onto a level, non-absorptive ...

  6. Duff Abrams - Wikipedia

    en.wikipedia.org/wiki/Duff_Abrams

    Abrams investigated the influence of the composition of concrete mixes on the strength of the end product. Some of the results of his research were: the definition of the concept of fineness modulus; the definition of the water–cement ratio; a concrete slump test for the

  7. Angle of repose - Wikipedia

    en.wikipedia.org/wiki/Angle_of_repose

    There are numerous methods for measuring angle of repose and each produces slightly different results. Results are also sensitive to the exact methodology of the experimenter. As a result, data from different labs are not always comparable. One method is the triaxial shear test, another is the direct shear test.

  8. Self-consolidating concrete - Wikipedia

    en.wikipedia.org/wiki/Self-consolidating_concrete

    Self-consolidating concrete or self-compacting concrete (SCC) [1] is a concrete mix which has a low yield stress, high deformability, good segregation resistance (prevents separation of particles in the mix), and moderate viscosity (necessary to ensure uniform suspension of solid particles during transportation, placement (without external compaction), and thereafter until the concrete sets).

  9. Water–cement ratio - Wikipedia

    en.wikipedia.org/wiki/Water–cement_ratio

    The effect of the water-to-cement (w/c) ratio onto the mechanical strength of concrete was first studied by René Féret (1892) in France, and then by Duff A. Abrams (1918) (inventor of the concrete slump test) in the USA, and by Jean Bolomey (1929) in Switzerland.