When.com Web Search

  1. Ad

    related to: circular bubble level for camera lens in microscope image labeled view of face

Search results

  1. Results From The WOW.Com Content Network
  2. Diffraction-limited system - Wikipedia

    en.wikipedia.org/wiki/Diffraction-limited_system

    In a digital camera, diffraction effects interact with the effects of the regular pixel grid. The combined effect of the different parts of an optical system is determined by the convolution of the point spread functions (PSF). The point spread function of a diffraction limited circular-aperture lens is simply the Airy disk. The point spread ...

  3. Phase-contrast microscopy - Wikipedia

    en.wikipedia.org/wiki/Phase-contrast_microscopy

    In a phase-contrast microscope, image contrast is increased in two ways: by generating constructive interference between scattered and background light rays in regions of the field of view that contain the specimen, and by reducing the amount of background light that reaches the image plane. [4]

  4. Light sheet fluorescence microscopy - Wikipedia

    en.wikipedia.org/wiki/Light_sheet_fluorescence...

    Most light sheet fluorescence microscopes are used to produce 3D images of the sample by moving the sample through the image plane. If the sample is larger than the field of view of the image sensor, the sample also has to be shifted laterally. An alternative approach is to move the image plane through the sample to create the image stack. [32]

  5. Differential interference contrast microscopy - Wikipedia

    en.wikipedia.org/wiki/Differential_interference...

    The light also carries information about the image invisible to the human eye, the phase of the light. This is vital later. The different polarisations prevent interference between these two images at this point. 5. The rays travel through the objective lens and are focused for the second Nomarski-modified Wollaston prism. 6.

  6. Point spread function - Wikipedia

    en.wikipedia.org/wiki/Point_spread_function

    By virtue of the linearity property of optical non-coherent imaging systems, i.e., . Image(Object 1 + Object 2) = Image(Object 1) + Image(Object 2). the image of an object in a microscope or telescope as a non-coherent imaging system can be computed by expressing the object-plane field as a weighted sum of 2D impulse functions, and then expressing the image plane field as a weighted sum of the ...

  7. Bright-field microscopy - Wikipedia

    en.wikipedia.org/wiki/Bright-field_microscopy

    A bright-field microscope has many important parts including; the condenser, the objective lens, the ocular lens, the diaphragm, and the aperture. Some other pieces of the microscope that are commonly known are the arm, the head, the illuminator, the base, the stage, the adjusters, and the brightness adjuster.

  8. Condenser (optics) - Wikipedia

    en.wikipedia.org/wiki/Condenser_(optics)

    The focus of the first lens is traditionally about 2mm away from the plane face coinciding with the sample plane. A pinhole cap can be used to align the optical axis of the condenser with that of the microscope. The Abbe condenser is still the basis for most modern light microscope condenser designs, even though its optical performance is poor.

  9. Polarized light microscopy - Wikipedia

    en.wikipedia.org/wiki/Polarized_light_microscopy

    Polarizing microscope operating principle Depiction of internal organs of a midge larva via birefringence and polarized light microscopy. Polarized light microscopy can mean any of a number of optical microscopy techniques involving polarized light. Simple techniques include illumination of the sample with polarized light.