United Kingdom: D, M [67] G [68] BS 546 BS 1363 230 V [69] 400 V 50 Hz Type D mostly historical, nowadays used only for remotely switched lighting and similar. Type M historically used in domestic installations, now only for stage lighting (where they are increasingly replaced with Ceeform). Bathrooms may have shaver supply units. United States ...
The United States National Electrical Code (NEC) specifies minimum acceptable wiring methods and materials for many states and municipalities. [2] It is sponsored by the National Fire Protection Association (NFPA) and has been periodically revised since 1897. Local jurisdictions usually adopt the NEC or another published code and then ...
United States electricity production by type. The United States has the second largest electricity sector in the world, with 4,178 Terawatt-hours of generation in 2023. [2] In 2023 the industry earned $491b in revenue (1.8% of GDP) at an average price of $0.127/kWh.
The waveform of 230 V and 50 Hz compared with 120 V and 60 Hz. The utility frequency, (power) line frequency (American English) or mains frequency (British English) is the nominal frequency of the oscillations of alternating current (AC) in a wide area synchronous grid transmitted from a power station to the end-user.
In the United States [13] [14] and Canada, [15] national standards specify that the nominal voltage at the source should be 120 V and allow a range of 114 V to 126 V (−5% to +5%). Historically, 110 V, 115 V and 117 V have been used at different times and places in North America.
NEMA 1-15P (two-pole, no ground) and NEMA 5-15P (two-pole with ground pin) plugs are used on common domestic electrical equipment, and NEMA 5-15R is the standard 15-ampere electric receptacle (outlet) found in the United States, and under relevant national standards, in Canada (CSA C22.2 No. 42 [1]), Mexico (NMX-J-163-ANCE) and Japan (JIS C 8303).
In the United States it is not usually used for three phase power but for the high leg delta wiring of split-phase electric power (unknown in Europe). This allows one to choose single-phase AC power at either 110–120 volts between phase and neutral or 220–240 volts between phase and phase.
Title 47 CFR Part 68 is a section of the Code of Federal Regulations of the United States that regulates the direct electrical connection of telecommunications equipment and customer premises wiring with the public switched telephone network, certain private line services, and connection of private branch exchange (PBX) equipment to certain telecommunication interfaces.