Drainage gradient (DG) is a term in road design, defined as the combined slope due to road surface cross slope (CS) and longitudinal slope (hilliness). Although the term may not be used, the concept is also used in roof design and landscape architecture. If the drainage gradient is too low, rain and melt water drainage will be insufficient.
Cross slope, cross fall or camber is a geometric feature of pavement surfaces: the transverse slope with respect to the horizon. It is a very important safety factor. Cross slope is provided to provide a drainage gradient so that water will run off the surface to a drainage system such as a street gutter or ditch.
the design drain spacing (L) can be found from the equation in dependence of the drain depth (Dd) and drain radius (r). Drainage criteria One would not want the water table to be too shallow to avoid crop yield depression nor too deep to avoid drought conditions. This is a subject of drainage research.
Grade, pitch, and slope are important components in landscape design, garden design, landscape architecture, and architecture; for engineering and aesthetic design factors. Drainage, slope stability, circulation of people and vehicles, complying with building codes, and design integration are all aspects of slope considerations in environmental ...
Section through railway track and foundation showing the sub-grade. Grading in civil engineering and landscape architectural construction is the work of ensuring a level base, or one with a specified slope, [1] for a construction work such as a foundation, the base course for a road or a railway, or landscape and garden improvements, or surface drainage.
In places with higher truck traffic, over 250 directional design hour volume, wider shoulders should be considered. Pavement sloping: On straight sections of the highway, the roadway is to have a cross slope of at least 1.5%, and preferably 2% to ensure proper drainage, with up to 2.5% in areas of heavy rainfall. The cross slope of both the ...
[4]: 144 Drainage, frost penetration and external loads such as wind and hydrostatic forces also have to be determined and included in the final examination of the design. [4]: 144 Soil nail walls are not ideal in locations with highly plastic clay soils. Soils with high plasticity, a high liquid limit and low undrained shear strengths are at ...
In water supply system drawing there will be hot water piping and cold water piping and hot water return piping also. In drainage system drawings there will be waste piping, Soil piping and vent piping. The set of drawing of each system like water supply, drainage etc is consist of Plans, Riser diagram, Installation details, Legends, Notes.