When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Mathematics of three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Mathematics_of_three-phase...

    Such arrays will evenly balance the polyphase load between the phases of the source system. For example, balanced two-phase power can be obtained from a three-phase network by using two specially constructed transformers, with taps at 50% and 86.6% of the primary voltage.

  3. Load balancing (electrical power) - Wikipedia

    en.wikipedia.org/wiki/Load_balancing_(electrical...

    Electrical substation. Load balancing, load matching, or daily peak demand reserve refers to the use of various techniques by electrical power stations to store excess electrical power during low demand periods for release as demand rises. [1] The aim is for the power supply system to have a load factor of 1.

  4. Balanced circuit - Wikipedia

    en.wikipedia.org/wiki/Balanced_circuit

    Balanced lines are a common method of transmitting many types of electrical signals between two points on two wires. In a balanced line, the two signal lines are of a matched impedance to help ensure that interference , induced in the line, is common-mode and can be removed at the receiving end by circuitry with good common-mode rejection .

  5. Unbalanced circuit - Wikipedia

    en.wikipedia.org/wiki/Unbalanced_circuit

    Comparison of unbalanced (A) and balanced (B) simple low-pass filters. The figure shows two versions of a simple low-pass filter, unbalanced version (A) and balanced version (B). Both circuits have exactly the same effect as filters, they have the same transfer function. However, on the unbalanced circuit, the bottom pole of the input port is ...

  6. Symmetrical components - Wikipedia

    en.wikipedia.org/wiki/Symmetrical_components

    Set of three unbalanced phasors, and the necessary symmetrical components that sum up to the resulting plot at the bottom. In 1918 Charles Legeyt Fortescue presented a paper [4] which demonstrated that any set of N unbalanced phasors (that is, any such polyphase signal) could be expressed as the sum of N symmetrical sets of balanced phasors, for values of N that are prime.

  7. Balun - Wikipedia

    en.wikipedia.org/wiki/Balun

    A balun / ˈ b æ l ʌ n / (from "balanced to unbalanced", originally, but now derived from "balancing unit") [1] is an electrical device that allows balanced and unbalanced lines to be interfaced without disturbing the impedance arrangement of either line. [2] A balun can take many forms and may include devices that also transform impedances ...

  8. Load management - Wikipedia

    en.wikipedia.org/wiki/Load_management

    Since electrical energy is a form of energy that cannot be effectively stored in bulk, it must be generated, distributed, and consumed immediately. When the load on a system approaches the maximum generating capacity, network operators must either find additional supplies of energy or find ways to curtail the load, hence load management.

  9. Electric power transmission - Wikipedia

    en.wikipedia.org/wiki/Electric_power_transmission

    The load control signals can either be sent on separate lines or on the power lines themselves. Voltage and frequency can be used as signaling mechanisms to balance the loads. In voltage signaling, voltage is varied to increase generation. The power added by any system increases as the line voltage decreases. This arrangement is stable in ...