Cement board is composed of aggregated Portland cement with a glass-fiber mesh on the surfaces. This 5 ⁄ 16 inch (7.9 mm) thick cement board is designed as an underlayment for tile floors. These are 3-by-5-foot (91 by 152 cm) sheets.
Sheet sizes vary slightly from manufacturer to manufacturer but generally they range between 2400 – 3000 mm in length and 900 –1200mm in width (600 & 450 mm increments). This manufactured size minimizes on-site wastage as residential floor, wall and roof structures lay structural members at 450 or 600mm centres.
Flat sheets for house walls and ceilings were usually 6 and 4.5 mm (0.24 and 0.18 in) thick, 900 and 1,200 mm (35 and 47 in) wide, and from 1,800 to 3,000 mm (71 to 118 in) long. Battens 50 mm (2.0 in) wide × 8 mm (0.31 in) thick, used to cover the joints in fibro sheets. "Super Six" corrugated roof sheeting and fencing. Internal wet area ...
In fibre cement there is a fibre reinforcement, which contributes to making the fibre-cement material even stronger. Together with a carefully planned production process, fibre cement makes it possible to develop strong and long lasting construction materials . [ 1 ]
This information is available in Victor C. Li's article on (ECC)- Tailored Composites through Micromechanical Modeling. [1] The first property listed, the ultimate tensile strength of 4.6 MPa, is slightly larger than the accepted tensile strength of standard fiber-reinforced concretes, (4.3 MPa). More notable, however, is the extremely high ...
To ensure that each fiber strand is effective, it is recommended to use fibers longer than the maximum aggregate size. Normal concrete contains 19 mm (0.75 in) equivalent diameter aggregate which is 35-45% of concrete, fibers longer than 20 mm (0.79 in) are more effective.
Transite originated as a brand that Johns Manville, an American company, created in 1929 for a line of asbestos-cement products, including boards and pipes. [1] In time it became a generic term for other companies' similar asbestos-cement products, and later an even more generic term for a hard, fireproof composite material , fibre cement ...
A 20 mm-thick layer of ECC was applied by spraying over the 600 m 2 surface. Also in 2003, an earth retaining wall in Gifu, Japan, was repaired using ECC. [11] Ordinary portland cement could not be used due to the severity of the cracking in the original structure, which would have caused reflective cracking. ECC was intended to minimize this ...