When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Instrumentation amplifier - Wikipedia

    en.wikipedia.org/wiki/Instrumentation_amplifier

    An instrumentation amplifier (sometimes shorthanded as in-amp or InAmp) is a type of differential amplifier that has been outfitted with input buffer amplifiers, which eliminate the need for input impedance matching and thus make the amplifier particularly suitable for use in measurement and test equipment. Additional characteristics include ...

  3. Isolation amplifier - Wikipedia

    en.wikipedia.org/wiki/Isolation_amplifier

    Isolation amplifiers are a form of differential amplifier that allow measurement of small signals in the presence of a high common mode voltage by providing electrical isolation and an electrical safety barrier. They protect data acquisition components from common mode voltages, which are potential differences between instrument ground and ...

  4. Signal conditioning - Wikipedia

    en.wikipedia.org/wiki/Signal_conditioning

    Signal conditioning. In electronics and signal processing, signal conditioning is the manipulation of an analog signal in such a way that it meets the requirements of the next stage for further processing. In an analog-to-digital converter (ADC) application, signal conditioning includes voltage or current limiting and anti-aliasing filtering ...

  5. Operational amplifier - Wikipedia

    en.wikipedia.org/wiki/Operational_amplifier

    An operational amplifier (often op amp or opamp) is a DC-coupled electronic voltage amplifier with a differential input, a (usually) single-ended output, [1] and an extremely high gain. Its name comes from its original use of performing mathematical operations in analog computers.

  6. Lock-in amplifier - Wikipedia

    en.wikipedia.org/wiki/Lock-in_amplifier

    Lock-in amplifier. A lock-in amplifier is a type of amplifier that can extract a signal with a known carrier wave from an extremely noisy environment. Depending on the dynamic reserve of the instrument, signals up to a million times smaller than noise components, potentially fairly close by in frequency, can still be reliably detected. It is ...

  7. Negative-feedback amplifier - Wikipedia

    en.wikipedia.org/wiki/Negative-feedback_amplifier

    Paul Voigt patented a negative feedback amplifier in January 1924, though his theory lacked detail. [4] Harold Stephen Black independently invented the negative-feedback amplifier while he was a passenger on the Lackawanna Ferry (from Hoboken Terminal to Manhattan) on his way to work at Bell Laboratories (located in Manhattan instead of New Jersey in 1927) on August 2, 1927 [5] (US Patent ...

  8. Bioinstrumentation - Wikipedia

    en.wikipedia.org/wiki/Bioinstrumentation

    Bioinstrumentation or Biomedical Instrumentation is an application of biomedical engineering which focuses on development of devices and mechanics used to measure, evaluate, and treat biological systems. The goal of biomedical instrumentation focuses on the use of multiple sensors to monitor physiological characteristics of a human or animal ...

  9. Closed-loop transfer function - Wikipedia

    en.wikipedia.org/wiki/Closed-loop_transfer_function

    The closed-loop transfer function is measured at the output. The output signal can be calculated from the closed-loop transfer function and the input signal. Signals may be waveforms, images, or other types of data streams. An example of a closed-loop block diagram, from which a transfer function may be computed, is shown below: