Ads
related to: cooling tower louvers diagram printable worksheet free for preschool letter f activities
Search results
Results From The WOW.Com Content Network
A typical evaporative, forced draft open-loop cooling tower rejecting heat from the condenser water loop of an industrial chiller unit Natural draft wet cooling hyperboloid towers at Didcot Power Station (UK) Forced draft wet cooling towers (height: 34 meters) and natural draft wet cooling tower (height: 122 meters) in Westphalia, Germany Natural draft wet cooling tower in Dresden (Germany)
Mechanical equipment (elevator engine, cooling tower, and boiler) serving a high rise condominium, concealed within a decorative concrete enclosure to match the exterior of building The mechanical penthouse (housing HVAC machinery) of Dodd Hall at UCLA is seen disguised as a bell tower with louvers provided for ventilation.
The first of the cooling load factors used in this method is the CLTD, or the Cooling Load Temperature Difference. This factor is used to represent the temperature difference between indoor and outdoor air with the inclusion of the heating effects of solar radiation. [1] [5] The second factor is the CLF, or the cooling load factor.
In about 1950 a hyperbolic reinforced concrete cooling tower was built with a capacity of 2.5 million gallons per hour (3.15 m 3 /s), with cooling range of 15 °F (8.3 °C). [12] However, there were complaints that operation of the cooling tower let to problems with ice in cold weather as water vapour from the tower froze as fine particles. [13]
Main page; Contents; Current events; Random article; About Wikipedia; Contact us; Pages for logged out editors learn more
A louver (American English) or louvre (Commonwealth English; see spelling differences) is a window blind or shutter with horizontal slats that are angled to admit light and air, but to keep out rain and direct sunshine. The angle of the slats may be adjustable, usually in blinds and windows, or fixed.
The evaporative cooling within a windtower causes the air in the tower to sink, driving circulation. This is called passive downdraught evaporative cooling (PDEC). It may also be generated using spray nozzles (which have a tendency to get blocked if the water is hard) or cold-water cooling coils (like hydronic underfloor heating in reverse).
Specific spray pond surface areas tend to range between 1.2 and 1.7 m 2 per m 3 /h of water to be cooled. The width chosen for a drift channel around the active zone of the pond (containing the sprays) is dependent on a number of factors, including the prevailing wind strength, the average size of the spray droplets produced by the nozzles, and the presence of any nearby structures which may ...