When.com Web Search

  1. Ads

    related to: how to calculate peak load capacity formula for concrete driveway cost

Search results

  1. Results From The WOW.Com Content Network
  2. Concrete cone failure - Wikipedia

    en.wikipedia.org/wiki/Concrete_cone_failure

    The tension failure loads predicted by the CCD method fits experimental results over a wide range of embedment depth (e.g. 100 – 600 mm). [2] Anchor load bearing capacity provided by ACI 349 does not consider size effect, thus an underestimated value for the load-carrying capacity is obtained for large embedment depths.

  3. Size effect on structural strength - Wikipedia

    en.wikipedia.org/wiki/Size_Effect_on_Structural...

    For quasibrittle materials, measuring the size effect on the peak loads (and on the specimen softening after the peak load) is the simplest approach. Knowing the size effect is also important in the reverse sense—for micrometer scale devices if they are designed partly or fully on the basis of material properties measured more conveniently on ...

  4. Factor of safety - Wikipedia

    en.wikipedia.org/wiki/Factor_of_safety

    In engineering, a factor of safety (FoS) or safety factor (SF) expresses how much stronger a system is than it needs to be for an intended load.Safety factors are often calculated using detailed analysis because comprehensive testing is impractical on many projects, such as bridges and buildings, but the structure's ability to carry a load must be determined to a reasonable accuracy.

  5. Strength of materials - Wikipedia

    en.wikipedia.org/wiki/Strength_of_materials

    The stresses and strains that develop within a mechanical member must be calculated in order to assess the load capacity of that member. This requires a complete description of the geometry of the member, its constraints, the loads applied to the member and the properties of the material of which the member is composed.

  6. Permissible stress design - Wikipedia

    en.wikipedia.org/wiki/Permissible_stress_design

    Permissible stress design is a design philosophy used by mechanical engineers and civil engineers. [1] [2]The civil designer ensures that the stresses developed in a structure due to service loads do not exceed the elastic limit.

  7. Compressive strength - Wikipedia

    en.wikipedia.org/wiki/Compressive_strength

    The characteristic strength is defined as the strength of the concrete below which not more than 5% of the test results are expected to fall. [ 16 ] For design purposes, this compressive strength value is restricted by dividing with a factor of safety, whose value depends on the design philosophy used.

  8. Peak demand - Wikipedia

    en.wikipedia.org/wiki/Peak_demand

    Peak demand is typically characterized as annual, daily or seasonal and has the unit of power. [1] Peak demand, peak load or on-peak are terms used in energy demand management describing a period in which electrical power is expected to be provided for a sustained period at a significantly higher than average supply level. Peak demand ...

  9. Mohr–Coulomb theory - Wikipedia

    en.wikipedia.org/wiki/Mohr–Coulomb_theory

    Mohr–Coulomb theory is a mathematical model (see yield surface) describing the response of brittle materials such as concrete, or rubble piles, to shear stress as well as normal stress. Most of the classical engineering materials follow this rule in at least a portion of their shear failure envelope.