Ads
related to: r12 to r134a refrigerant conversion chart printable
Search results
Results From The WOW.Com Content Network
Automobile manufacturers began phasing in R-134a around 1993 [citation needed]. When older units leak or require repair involving removal of the refrigerant, retrofitment to a refrigerant other than R-12 (most commonly R-134a) is required in some jurisdictions. The United States does not require such conversion.
HC-12a, also called ES-12a, OZ-12a, DURACOOL 12a [1] and Hydrocarbon Blend B, is marketed as a "drop-in" replacement refrigerant for R-12 and other refrigerants. HC-12a is a mixture of hydrocarbons, specifically propane (R-290) and isobutane (R-600a), and is therefore considered nearly non-ozone-depleting.
According to ASHRAE standard 34, the R-number of a chemical refrigerant is assigned systematically according to its molecular structure and has between two and four digits. If there are carbon -carbon multiple bonds , there are four digits in all: the number of these bonds is the first digit and the number of carbon atoms minus one (C-1) is next.
1,1,1,2-Tetrafluoroethane (also known as norflurane (), R-134a, Klea 134a, Freon 134a, Forane 134a, Genetron 134a, Green Gas, Florasol 134a, Suva 134a, HFA-134a, or HFC-134a) is a hydrofluorocarbon (HFC) and haloalkane refrigerant with thermodynamic properties similar to R-12 (dichlorodifluoromethane) but with insignificant ozone depletion potential and a lower 100-year global warming ...
CARE 30 is a refrigerant consisting of a blend of isobutane (R-600a) and propane (R-290) developed to replace dichlorodifluoromethane (R-12) and 1,1,1,2-tetrafluoroethane (R-134a). [1] It is primarily for use in small commercial refrigeration and air-conditioning systems that have traditionally used R-12.
Dichlorodifluoromethane (R-12 or CFC-12), the most commonly used Freon brand refrigerant prior to its ban in many countries in 1996 and total ban in 2010. 1,1,1,2-Tetrafluoroethane (R-134a or HFC-134a), one of the main replacements for the formerly widespread R-12. Opteon halogenated olefins now replacing Freons in many applications.
They are frequently used in air conditioning and as refrigerants; R-134a (1,1,1,2-tetrafluoroethane) is one of the most commonly used HFC refrigerants. In order to aid the recovery of the stratospheric ozone layer, HFCs were adopted to replace the more potent chlorofluorocarbons (CFCs), which were phased out from use by the Montreal Protocol ...
The refrigerant was developed by the DuPont/Honeywell company and is more expensive per pound than R-134a. R-1234yf can be found in late-model cars and is not cross-compatible with older R-134a or R-12 systems. Of the three refrigerants, R-1234yf is the best for the environment with the lowest global warming potential number which is about a three.