When.com Web Search

  1. Ads

    related to: 100 ton water cooled chiller

Search results

  1. Results From The WOW.Com Content Network
  2. Water chiller - Wikipedia

    en.wikipedia.org/wiki/Water_chiller

    In air conditioning, chilled water is often used to cool a building's air and equipment, especially in situations where many individual rooms must be controlled separately, such as a hotel. A chiller lowers water temperature to between 40 °F (4 °C) and 45 °F (7 °C) before the water is pumped to the location to be cooled. [2]

  3. Chiller - Wikipedia

    en.wikipedia.org/wiki/Chiller

    A liquid (glycol based) chiller with an air cooled condenser on the rooftop of a medium size commercial building. In air conditioning systems, chilled coolant, usually chilled water mixed with ethylene glycol, from a chiller in an air conditioning or cooling plant is typically distributed to heat exchangers, or coils, in air handlers or other types of terminal devices which cool the air in ...

  4. Ton of refrigeration - Wikipedia

    en.wikipedia.org/wiki/Ton_of_refrigeration

    Just as horsepower and candlepower were intuitive units of measure for people living through the transition from horse to steam power [3] and from flame-based to electric lighting, so was the ton of refrigeration an intuitive unit of measure during a technological change, as the ice trade gradually included growing percentages of artificial ice ...

  5. Cooling tower - Wikipedia

    en.wikipedia.org/wiki/Cooling_tower

    Liquid-cooled chillers are normally more energy efficient than air-cooled chillers due to heat rejection to tower water at or near wet-bulb temperatures. Air-cooled chillers must reject heat at the higher dry-bulb temperature, and thus have a lower average reverse–Carnot-cycle effectiveness. In hot climates, large office buildings, hospitals ...

  6. Coefficient of performance - Wikipedia

    en.wikipedia.org/wiki/Coefficient_of_performance

    The COP of absorption chillers can be improved by adding a second or third stage. Double and triple effect chillers are significantly more efficient than single effect chillers, and can surpass a COP of 1. They require higher pressure and higher temperature steam, but this is still a relatively small 10 pounds of steam per hour per ton of cooling.

  7. Vapor-compression refrigeration - Wikipedia

    en.wikipedia.org/wiki/Vapor-compression...

    A representative pressure–volume diagram for a refrigeration cycle. Vapour-compression refrigeration or vapor-compression refrigeration system (VCRS), [1] in which the refrigerant undergoes phase changes, is one of the many refrigeration cycles and is the most widely used method for air conditioning of buildings and automobiles.

  1. Ad

    related to: 100 ton water cooled chiller