When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Standard cubic feet per minute - Wikipedia

    en.wikipedia.org/wiki/Standard_cubic_feet_per_minute

    Xchanger Inc, webpage Calculator for SCFM, NM3/hr, lb/hr, kg/hr, ACFM & M3/hr gas flows. onlineflow.de, webpage Online calculator for conversion of volume, mass and molar flows (SCFM, MMSCFD, Nm3/hr, kg/s, kmol/hr and more) ACFM versus SCFM for ASME AG-1 HEPA Filters; SCFM (Standard CFM) vs. ACFM (Actual CFM) (Specifically for air flows only)

  3. Actual cubic feet per minute - Wikipedia

    en.wikipedia.org/wiki/Actual_cubic_feet_per_minute

    Actual cubic feet per minute (ACFM) is a unit of volumetric flow. It is commonly used by manufacturers of blowers and compressors. [1] This is the actual gas delivery with reference to inlet conditions, whereas cubic foot per minute (CFM) is an unqualified term and should only be used in general and never accepted as a specific definition without explanation.

  4. Volume units used in petroleum engineering - Wikipedia

    en.wikipedia.org/wiki/Volume_units_used_in...

    Oil conversion factor from m³ to bbl (or stb) is 6.28981100; Gas conversion factor from standard m³ to scf is 35.314666721; Note that the m³ gas conversion factor takes into account a difference in the standard temperature base for measurement of gas volumes in metric and imperial units.

  5. Useful conversions and formulas for air dispersion modeling

    en.wikipedia.org/wiki/Useful_conversions_and...

    As an example, given a concentration of 260 mg/m 3 at sea level, calculate the equivalent concentration at an altitude of 1,800 meters: C a = 260 × 0.9877 18 = 208 mg/m 3 at 1,800 meters altitude Standard conditions for gas volumes

  6. Volumetric flow rate - Wikipedia

    en.wikipedia.org/wiki/Volumetric_flow_rate

    The area required to calculate the volumetric flow rate is real or imaginary, flat or curved, either as a cross-sectional area or a surface. The vector area is a combination of the magnitude of the area through which the volume passes through, A , and a unit vector normal to the area, n ^ {\displaystyle {\hat {\mathbf {n} }}} .

  7. Airwatt - Wikipedia

    en.wikipedia.org/wiki/Airwatt

    Where airflow in Cubic Feet per Minute [CFM] is calculated using airflow = √ 13.35 × D 2 / vacuum. Where D is the diameter of the orifices. [5] [further explanation needed] CFM is always given statistically at its maximum which is at a 2-inch (51 mm) opening. Waterlift, on the other hand, is always given at its maximum: a 0-inch opening.

  8. Standard cubic centimetres per minute - Wikipedia

    en.wikipedia.org/wiki/Standard_cubic_centimetres...

    One example of standard conditions for the calculation of SCCM is = 0 °C (273.15 K) [1] and = 1.01 bar (14.72 psia) and a unity compressibility factor = 1 (i.e., an ideal gas is used for the definition of SCCM). [2] This example is for the semi-conductor-manufacturing industry.

  9. Conversion of units - Wikipedia

    en.wikipedia.org/wiki/Conversion_of_units

    In the cases where non-SI units are used, the numerical calculation of a formula can be done by first working out the factor, and then plug in the numerical values of the given/known quantities. For example, in the study of Bose–Einstein condensate , [ 6 ] atomic mass m is usually given in daltons , instead of kilograms , and chemical ...