Search results
Results From The WOW.Com Content Network
A phase detector or phase comparator is a frequency mixer, analog multiplier or logic circuit that generates a signal which represents the difference in phase between two signal inputs. The phase detector is an essential element of the phase-locked loop (PLL). Detecting phase difference is important in other applications, such as motor control ...
If two electrical networks operating at two different phase angles were to be connected to each other, a fault similar to a short circuit would occur, presenting a hazard of damage to the generator or other equipment. The position (as opposed to rotation) of the pointer on a synchroscope indicates the phase angle between the two systems.
Two-phase power can be derived from a three-phase source using two transformers in a Scott connection: One transformer primary is connected across two phases of the supply. The second transformer is connected to a center-tap of the first transformer, and is wound for 86.6% of the phase-to-phase voltage on the three-phase system.
A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...
In 2015, Texas Instruments announced the ATL431, an improved derivative of the TL431 for very high efficiency switch-mode regulators [49] that has a V REF of 2.5 V instead of 2.495 V. The recommended minimum operating current is only 35 μA (standard TL431: 1 mA); the maximum I CA and V CA are the same as standard (100 mA and 36 V). [ 50 ]
Using a PMU, it is simple to detect abnormal waveform shapes. A waveform shape described mathematically is called a phasor.. A phasor measurement unit (PMU) is a device used to estimate the magnitude and phase angle of an electrical phasor quantity (such as voltage or current) in the electricity grid using a common time source for synchronization.
One voltage cycle of a three-phase system. A polyphase system (the term coined by Silvanus Thompson) is a means of distributing alternating-current (AC) electrical power that utilizes more than one AC phase, which refers to the phase offset value (in degrees) between AC in multiple conducting wires; phases may also refer to the corresponding terminals and conductors, as in color codes.
A GCM or ground continuity monitor (also called a ground integrity monitor or ground continuity tester) is an electrical safety device that monitors the impedance to ground of a temporary electrical circuit and can provide indication (or protective trip) in the event impedance rises to an unsafe value. A GCM is either an external testing device ...