When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Ground continuity monitor - Wikipedia

    en.wikipedia.org/wiki/Ground_continuity_monitor

    A GCM or ground continuity monitor (also called a ground integrity monitor or ground continuity tester) is an electrical safety device that monitors the impedance to ground of a temporary electrical circuit and can provide indication (or protective trip) in the event impedance rises to an unsafe value. A GCM is either an external testing device ...

  3. Two-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Two-phase_electric_power

    Two-phase power can be derived from a three-phase source using two transformers in a Scott connection: One transformer primary is connected across two phases of the supply. The second transformer is connected to a center-tap of the first transformer, and is wound for 86.6% of the phase-to-phase voltage on the three-phase system.

  4. Electrical isolation test - Wikipedia

    en.wikipedia.org/wiki/Electrical_isolation_test

    The test often reveals problems that occurred during assembly, such as defective components, improper component placement, and insulator defects that may cause inadvertent shorting or grounding to chassis, in turn, compromising electrical circuit quality and product safety. [2]

  5. Phase detector - Wikipedia

    en.wikipedia.org/wiki/Phase_detector

    A phase detector or phase comparator is a frequency mixer, analog multiplier or logic circuit that generates a signal which represents the difference in phase between two signal inputs. The phase detector is an essential element of the phase-locked loop (PLL). Detecting phase difference is important in other applications, such as motor control ...

  6. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...

  7. Synchroscope - Wikipedia

    en.wikipedia.org/wiki/Synchroscope

    If two electrical networks operating at two different phase angles were to be connected to each other, a fault similar to a short circuit would occur, presenting a hazard of damage to the generator or other equipment. The position (as opposed to rotation) of the pointer on a synchroscope indicates the phase angle between the two systems.

  8. LCR meter - Wikipedia

    en.wikipedia.org/wiki/LCR_meter

    An LCR meter is a type of electronic test equipment used to measure the inductance (L), capacitance (C), and resistance (R) of an electronic component. [1] In the simpler versions of this instrument the impedance was measured internally and converted for display to the corresponding capacitance or inductance value.

  9. Current clamp - Wikipedia

    en.wikipedia.org/wiki/Current_clamp

    An electrical meter with integral AC current clamp is known as a clamp meter, clamp-on ammeter, tong tester, or colloquially as an amp clamp. A clamp meter measures the vector sum of the currents flowing in all the conductors passing through the probe, which depends on the phase relationship of the currents. Only one conductor is normally ...

  1. Related searches how to switch dominant monitor to 2 phase circuit tester calculator manual

    phase detector diagramdigital phase detector
    phase detector type 1phase frequency sensor
    phase detectormotorola phase detector