Attenuation decreases the intensity of electromagnetic radiation due to absorption or scattering of photons. Attenuation does not include the decrease in intensity due to inverse-square law geometric spreading. Therefore, calculation of the total change in intensity involves both the inverse-square law and an estimation of attenuation over the ...
The absorption coefficient of a volume, denoted μ a, and the scattering coefficient of a volume, denoted μ s, are defined the same way as the attenuation coefficient. [ 6 ] The attenuation coefficient of a volume is the sum of absorption coefficient and scattering coefficients: [ 6 ]
The plot for vapor is a transformation of data Synthetic spectrum for gas mixture ' Pure H 2 O ' (296K, 1 atm) retrieved from Hitran on the Web Information System. [6] Liquid water absorption spectrum across a wide wavelength range [missing source] The absorption of electromagnetic radiation by water depends on the state of the water.
absorption coefficient is essentially (but not quite always) synonymous with attenuation coefficient; see attenuation coefficient for details; molar absorption coefficient or molar extinction coefficient , also called molar absorptivity , is the attenuation coefficient divided by molarity (and usually multiplied by ln(10), i.e., decadic); see ...
The spectrum of pure bilirubin is known, so the molar attenuation coefficient ε is known. Measurements of decadic attenuation coefficient μ 10 are made at one wavelength λ that is nearly unique for bilirubin and at a second wavelength in order to correct for possible interferences.
An overview of absorption of electromagnetic radiation.This example shows the general principle using visible light as a specific example. A white light source—emitting light of multiple wavelengths—is focused on a sample (the pairs of complementary colors are indicated by the yellow dotted lines).
The SI unit of molar absorption coefficient is the square metre per mole (m 2 /mol), but in practice, quantities are usually expressed in terms of M −1 ⋅cm −1 or L⋅mol −1 ⋅cm −1 (the latter two units are both equal to 0.1 m 2 /mol).
The most straightforward approach to absorption spectroscopy is to generate radiation with a source, measure a reference spectrum of that radiation with a detector and then re-measure the sample spectrum after placing the material of interest in between the source and detector. The two measured spectra can then be combined to determine the ...