When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Electrocardiography - Wikipedia

    en.wikipedia.org/wiki/Electrocardiography

    Leads are broken down into three types: limb; augmented limb; and precordial or chest. The 12-lead ECG has a total of three limb leads and three augmented limb leads arranged like spokes of a wheel in the coronal plane (vertical), and six precordial leads or chest leads that lie on the perpendicular transverse plane (horizontal). [33]

  3. File:ECG limb and chest electrodes placement.png - Wikipedia

    en.wikipedia.org/wiki/File:ECG_limb_and_chest...

    You are free: to share – to copy, distribute and transmit the work; to remix – to adapt the work; Under the following conditions: attribution – You must give appropriate credit, provide a link to the license, and indicate if changes were made.

  4. Einthoven's triangle - Wikipedia

    en.wikipedia.org/wiki/Einthoven's_triangle

    Einthoven's triangle is an imaginary formation of three limb leads in a triangle used in the electrocardiography, formed by the two shoulders and the pubis. [1] The shape forms an inverted equilateral triangle with the heart at the center. It is named after Willem Einthoven, who theorized its existence. [2]

  5. Holter monitor - Wikipedia

    en.wikipedia.org/wiki/Holter_monitor

    Each Holter system has hardware (called monitor or recorder) for recording the signal, and software for review and analysis of the record. There may be a "patient button" on the front that the patient can press at specific instants such as feeling/being sick, going to bed, taking pills, marking an event of symptoms which is then documented in the symptoms diary, etc.; this records a mark that ...

  6. ST elevation - Wikipedia

    en.wikipedia.org/wiki/ST_elevation

    An ST elevation is considered significant if the vertical distance inside the ECG trace and the baseline at a point 0.04 seconds after the J-point is at least 0.1 mV (usually representing 1 mm or 1 small square) in a limb lead or 0.2 mV (2 mm or 2 small squares) in a precordial lead. [2] The baseline is either the PR interval or the TP interval ...

  7. Left axis deviation - Wikipedia

    en.wikipedia.org/wiki/Left_axis_deviation

    The hexaxial reference system is a diagram that is used to determine the heart's electrical axis in the frontal plane.. In electrocardiography, left axis deviation (LAD) is a condition wherein the mean electrical axis of ventricular contraction of the heart lies in a frontal plane direction between −30° and −90°.

  8. Precordial concordance - Wikipedia

    en.wikipedia.org/wiki/Precordial_concordance

    Precordial concordance, also known as QRS concordance is when all precordial leads on an electrocardiogram are either positive (positive concordance) or negative (negative concordance). [1]

  9. Hexaxial reference system - Wikipedia

    en.wikipedia.org/wiki/Hexaxial_reference_system

    The hexaxial reference system is a diagram that is used to determine the heart's electrical axis in the frontal plane. The hexaxial reference system, better known as the Cabrera system, is a convention to present the extremity leads of the 12 lead electrocardiogram, [1] that provides an illustrative logical sequence that helps interpretation of the ECG, especially to determine the heart's ...