When.com Web Search

  1. Ads

    related to: mechanical draft cooling tower systems

Search results

  1. Results From The WOW.Com Content Network
  2. Cooling tower - Wikipedia

    en.wikipedia.org/wiki/Cooling_tower

    A typical evaporative, forced draft open-loop cooling tower rejecting heat from the condenser water loop of an industrial chiller unit Natural draft wet cooling hyperboloid towers at Didcot Power Station (UK) Forced draft wet cooling towers (height: 34 meters) and natural draft wet cooling tower (height: 122 meters) in Westphalia, Germany Natural draft wet cooling tower in Dresden (Germany)

  3. Circulating water plant - Wikipedia

    en.wikipedia.org/wiki/Circulating_Water_Plant

    In the present era, mechanical induced draft–type cooling towers are employed in cooling of water. Performance testing of cooling towers (both IDCT and NDCT) shall be carried out as per ATC-105 [4] at a time when the atmospheric conditions are within the permissible limits of deviation from the design conditions.

  4. Duane Arnold Energy Center - Wikipedia

    en.wikipedia.org/wiki/Duane_Arnold_Energy_Center

    Twenty-four mechanical draft cooling towers utilized water from the Cedar River as a heat sink. Facilities exist to process all contaminated water onsite and the DAEC operates with a "zero release" policy to not discharge any contaminated water back to the Cedar River.

  5. Water cooling - Wikipedia

    en.wikipedia.org/wiki/Water_cooling

    Large mechanical induced-draft or forced-draft cooling towers in industrial plants continuously circulate cooling water through heat exchangers and other equipment where the water absorbs heat. That heat is then rejected to the atmosphere by the evaporation of some of the water in cooling towers where upflowing air contacts the downflowing water.

  6. McKinley Climatic Laboratory - Wikipedia

    en.wikipedia.org/wiki/McKinley_Climatic_Laboratory

    The Building 440 is an insulated, refrigerated hangar. There is an office and instrumentation building, a cold-weather engine test cell, the refrigeration system, mechanical-draft cooling towers, and a steam-heating plant. [4] The main chamber is 252 feet (77 m) wide, 201 feet (61 m) deep, and 70 feet (21 m) tall at the center of the hangar.

  7. Thermal power station - Wikipedia

    en.wikipedia.org/wiki/Thermal_power_station

    This is done by pumping the warm water from the condenser through either natural draft, forced draft or induced draft cooling towers (as seen in the adjacent image) that reduce the temperature of the water by evaporation, by about 11 to 17 °C (52 to 63 °F)—expelling waste heat to the atmosphere.