A central heating system has a furnace that converts fuel or electricity to heat through processes. The heat is circulated through the building either by fans forcing heated air through ducts, circulation of low-pressure steam to radiators in each heated room, or pumps that circulate hot water through room radiators.
A thermostatic radiator valve on position 2 (15–17 °C) Installed thermostatic radiator valve with the adjustment wheel removed A thermostatic radiator valve (TRV) is a self-regulating valve fitted to hot water heating system radiator, to control the temperature of a room by changing the flow of hot water to the radiator.
A hot-water radiator consists of a sealed hollow metal container filled with hot water from a boiler or other heating device by gravity feed, a pump, or natural convection. As it gives out heat, the hot water cools and sinks to the bottom of the radiator and is forced out of a pipe at the other end.
They typically use low power heating elements, about 1 kW to 1.5 kW, and can provide hot water long enough for hand washing, or, if plumbed into an existing hot water line, until hot water arrives from a remote high capacity water heater. They may be used when retrofitting a building with hot water plumbing is too costly or impractical.
The thermostat controls the fan speed and/or the flow of water or refrigerant to the heat exchanger using a control valve. Due to their simplicity, flexibility, and easy maintenance, fan coil units can be more economical to install than ducted 100% fresh air systems (VAV) or central heating systems with air handling units or chilled beams. FCUs ...
The heat can be transferred to the surrounding air using radiators, hot water coils (hydro-air), or other heat exchangers. The radiators may be mounted on walls or installed within the floor to produce floor heat. The use of water as the heat transfer medium is known as hydronics. The heated water can also supply an auxiliary heat exchanger to ...
It is not affected by pipe diameter, room operative temperature, supply water temperature, and water flow regime. By using response time, radiant systems can be classified into fast response (τ95< 10 min, like RCP), medium response (1 h<τ95<9 h, like Type A, B, D, G) and slow response (9 h< τ95<19 h, like Type E and Type F). [ 40 ]
A thermostat exerts control by switching heating or cooling devices on or off, or by regulating the flow of a heat transfer fluid as needed, to maintain the correct temperature. A thermostat can often be the main control unit for a heating or cooling system, in applications ranging from ambient air control to automotive coolant control.