Search results

  1. Results From The WOW.Com Content Network
  2. Smoke damper - Wikipedia

    en.wikipedia.org/wiki/Smoke_damper

    Smoke damper may be used to prevent the spread of smoke from the space of fire origin to other spaces in the same building. A combination of fans and dampers can exhaust smoke from an area while pressurizing the smoke-free areas around the affected area (inhibiting smoke infiltration into additional areas).

  3. Pressurisation ductwork - Wikipedia

    en.wikipedia.org/wiki/Pressurisation_ductwork

    Pressurisation ductwork (sheet metal) externally fireproofed with pressed vermiculite boards, stapled together. Pressurisation ductwork made of Durasteel. Pressurisation ductwork is a passive fire protection system. It is used to supply fresh air to any area of refuge, designated emergency evacuation or egress route.

  4. Fire damper - Wikipedia

    en.wikipedia.org/wiki/Fire_damper

    Fire/smoke dampers are similar to fire dampers in fire resistance rating, and also prevent the spread of smoke inside the ducts. When a rise in temperature occurs, the fire damper closes, usually activated by a thermal element which melts at temperatures higher than ambient but low enough to indicate the presence of a fire, allowing springs to ...

  5. Passive fire protection - Wikipedia

    en.wikipedia.org/wiki/Passive_fire_protection

    In North America, grease ducts are made of minimum 16 gauge (1.6 mm) sheet metal, all welded, and certified openings for cleaning, whereby the ducting is either inherently manufactured to have a specific fire-resistance rating, OR it is ordinary 16 gauge ductwork with an exterior layer of purpose-made and certified fireproofing.

  6. Smoke exhaust ductwork - Wikipedia

    en.wikipedia.org/wiki/Smoke_exhaust_ductwork

    Smoke exhaust ductwork, in Europe, is typically protected via passive fire protection means, subject to fire testing (typically to NBN EN 1366-8 [1]) and listing and approval use and compliance. It is used to remove smoke from buildings , ships or offshore structures to enable emergency evacuation as well as improved firefighting.

  7. Grease duct - Wikipedia

    en.wikipedia.org/wiki/Grease_duct

    In North America, grease ducts must be in compliance with NFPA 96 as well as the local building codes and fire codes. [citation needed]A proprietary duct system that has its own inherent fire-resistance rating can be used, such as a metallic duct, either field fabricated or UL certified factory-built designs.

  8. Duct (flow) - Wikipedia

    en.wikipedia.org/wiki/Duct_(flow)

    Ducts for air pollution control in a 17000 standard cubic feet per minute regenerative thermal oxidizer (RTO). A round galvanized steel duct connecting to a typical diffuser Fire-resistance rated mechanical shaft with HVAC sheet metal ducting and copper piping, as well as "HOW" (Head-Of-Wall) joint between top of concrete block wall and underside of concrete slab, firestopped with ceramic ...

  9. Heat and smoke vent - Wikipedia

    en.wikipedia.org/wiki/Heat_and_smoke_vent

    The majority of guidance available for design of heat and smoke building vents installed in buildings is restricted to nonsprinklered, single-story buildings. [4] This is partly a historical consequence of the installation of heat and smoke vents following the August 1953 General Motors, Livonia, MI major fire in a nonsprinklered manufacturing facility which effectively stopped the production ...