Search results
Results From The WOW.Com Content Network
Committed equivalent dose, H T (t) is the time integral of the equivalent dose rate in a particular tissue or organ that will be received by an individual following intake of radioactive material into the body by a Reference Person, where s is the integration time in years. [13]
A dose rate is quantity of radiation absorbed or delivered per unit time. It is often indicated in micrograys per hour (μGy/h) [ 1 ] or as an equivalent dose rate Ḣ T in rems per hour (rem/hr) or sieverts per hour (Sv/h).
The equivalent dose is calculated by multiplying the absorbed energy, averaged by mass over an organ or tissue of interest, by a radiation weighting factor appropriate to the type and energy of radiation. To obtain the equivalent dose for a mix of radiation types and energies, a sum is taken over all types of radiation energy dose. [1]
CDE is defined by the United States Nuclear Regulatory Commission in Title 10, Section 20.1003, of the Code of Federal Regulations (10 CFR 20.1003), such that "The Committed dose equivalent, CDE (H T,50) is the dose to some specific organ or tissue of reference (T) that will be received from an intake of radioactive material by an individual during the 50-year period following the intake".
The dose equivalent is calculated by the following equation: [4] Dose equivalent = Absorbed dosage x Tissue weighting factor Tissue weighting factor reflects the relative sensitivity of each organ to radiation. [4] The effective dose refers to the radiation risk averaged over the entire body. [4] It is the sum of the equivalent dosage of all ...
Committed equivalent dose is the time integral of the equivalent dose rate in a particular tissue or organ that will be received by an individual following intake of radioactive material into the body by a Reference Person, where t is the integration time in years. [3]
The deterministic effects that can lead to acute radiation syndrome only occur in the case of high doses (> ~10 rad or > 0.1 Gy) and high dose rates (> ~10 rad/h or > 0.1 Gy/h). A model of deterministic risk would require different weighting factors (not yet established) than are used in the calculation of equivalent and effective dose.
Effective dose is a dose quantity in the International Commission on Radiological Protection (ICRP) system of radiological protection. [1]It is the tissue-weighted sum of the equivalent doses in all specified tissues and organs of the human body and represents the stochastic health risk to the whole body, which is the probability of cancer induction and genetic effects, of low levels of ...