    en.wikipedia.org/wiki/Registered_jack

    Cords connecting to an RJ11 interface require a 6P2C connector. Nevertheless, cords sold as RJ11 often use 6P4C connectors (six position, four conductor) with four wires. Two of the six possible contact positions connect tip and ring, and the other two conductors are unused. RJ11 is commonly used to connect DSL modems to the customer line.

  3. Ethernet crossover cable - Wikipedia

    en.wikipedia.org/wiki/Ethernet_crossover_cable

    A crossover cable may also be used to connect two hubs or two switches on their upstream ports. Because the only difference between the T568A and T568B pin and pair assignments are that pairs 2 and 3 are swapped, a crossover cable may be envisioned as a cable with one modular connector following T568A and the other T568B (see TIA/EIA-568 wiring ...

  4. Modular connector - Wikipedia

    en.wikipedia.org/wiki/Modular_connector

    An 8P8C modular plug. This is the common crimp-type plug, of the same kind pictured above crimped onto a cable (with molded sleeve). A modular connector is a type of electrical connector for cords and cables of electronic devices and appliances, such as in computer networking, telecommunication equipment, and audio headsets.

  5. Telephone jack and plug - Wikipedia

    en.wikipedia.org/wiki/Telephone_jack_and_plug

    For example, telephone cables in the UK typically have a BS 6312 (UK standard) plug at the wall end and a 6P4C or 6P2C modular connector at the telephone end: this latter may be wired as per the RJ11 standard (with pins 3 and 4), or it may be wired with pins 2 and 5, as a straight-through cable from the BT plug (which uses pins 2 and 5 for the ...

  6. Networking cable - Wikipedia

    en.wikipedia.org/wiki/Networking_cable

    A coaxial cable has a central conductor surrounded by a sheath of conductor with insulation in between. Coaxial cables form a transmission line and confine the electromagnetic wave to an area inside the cable between the center conductor and the shield. The transmission of energy in the line occurs totally through the dielectric inside the ...

  7. Category 5 cable - Wikipedia

    en.wikipedia.org/wiki/Category_5_cable

    Category 5 cable is nearly always terminated with 8P8C modular connectors (often referred to incorrectly as RJ45 connectors [14] [15] [16]). The cable is terminated in either the T568A scheme or the T568B scheme. The two schemes work equally well and may be mixed in an installation so long as the same scheme is used on both ends of each cable.

  8. Keystone module - Wikipedia

    en.wikipedia.org/wiki/Keystone_module

    Some keystones use a pass-through type connector, where there is a jack on both the front face and the rear side. Others only have a jack on the front and employ a different mechanism for hard-wiring signal cables to the rear, such as a mini 110 block , an insulation-displacement connector , or a crimp or solder connection.

  9. Medium-dependent interface - Wikipedia

    en.wikipedia.org/wiki/Medium-dependent_interface

    For 10BASE5, connection to the coaxial cable was made with either a vampire tap or a pair of N connectors. For 10BASE2, the connection to the coaxial cable was typically made with a single BNC connector to which a T-piece was attached. For twisted-pair cabling 8P8C, modular connectors are used (often called RJ45 in this context).