The SI unit of power for heating and cooling systems is the watt. Btu per hour (Btu/h) is sometimes used in North America and the United Kingdom - the latter for air conditioning mainly, though "Btu/h" is sometimes abbreviated to just "Btu". [18] MBH—thousands of Btu per hour—is also common. [19] 1 W is approximately 3.412142 Btu/h [20]
HSPF is defined as the ratio of heat output (measured in BTUs) over the heating season to electricity used (measured in watt-hours). [1][2] It therefore has units of BTU/watt-hr. The higher the HSPF rating of a unit, the more energy efficient it is. An electrical resistance heater, which is not considered efficient, has an HSPF of 3.41.
A ground source heat pump (also geothermal heat pump) is a heating/cooling system for buildings that use a type of heat pump to transfer heat to or from the ground, taking advantage of the relative constancy of temperatures of the earth through the seasons. Ground-source heat pumps (GSHPs) – or geothermal heat pumps (GHP), as they are ...
The EER uses mixed units, so it does not have an immediate physical sense and is obtained by multiplying the COP by the conversion factor from BTUs to watt-hours: EER = 3.41214 × COP (see British thermal unit). The seasonal energy efficiency ratio (SEER) is also the COP (or EER) expressed in BTU/watt-hour, but instead of being evaluated at a ...
Thermal transmittance. Thermal transmittance is the rate of transfer of heat through matter. The thermal transmittance of a material (such as insulation or concrete) or an assembly (such as a wall or window) is expressed as a U-value. The thermal insulance of a structure is the reciprocal of its thermal transmittance.
The R-value (in K ⋅ m 2/ W) is a measure of how well a two-dimensional barrier, such as a layer of insulation, a window or a complete wall or ceiling, resists the conductive [2] flow of heat, in the context of construction. [3]. R-value is the temperature difference per unit of heat flux needed to sustain one unit of heat flux between the ...
Therm. The therm (symbol, thm) is a non- SI unit of heat energy equal to 100,000 British thermal units (BTU), [1] and approximately 105 megajoules, 29.3 kilowatt-hours, 25,200 kilocalories and 25.2 thermies. One therm is the energy content of approximately 100 cubic feet (2.83 cubic metres) of natural gas at standard temperature and pressure.
The energy content of ethanol is 76,100 BTU/US gal (5.89 kilowatt-hours per litre), compared to 114,100 BTU/US gal (8.83 kWh/L) for gasoline. (see chart above) A flex-fuel vehicle will experience about 76% of the fuel mileage MPG when using E85 (85% ethanol) products as compared to 100% gasoline. Simple calculations of the BTU values of the ...