An optical beam smoke detector is a device that uses a projected beam of light to detect smoke across large areas, [1] typically as an indicator of fire. [2] They are used to detect fires in buildings where standard point smoke detectors would either be uneconomical [ 3 ] or restricted for use by the height of the building.
The NFPA 72 (National Fire Alarm and Signaling Code) is a standard published by the National Fire Protection Association every 3 years for installation of fire alarm systems and emergency communication systems in the United States.
The standard's current edition was designated as an American National Standard standard. Other standards, such as the IBC since 2012, [11] reference and require compliance with UL 294 (as of 2024, [12] either UL 294 or UL 1034) . The IBC references the UL standards for special locking arrangements, when egress requires the usage of special ...
A report by the UK-based Building Research Establishment (BRE) stated "there is a commonly held view that equipment designed to meet the European EN54 Fire detection and fire alarm systems standard cannot be used within an installation designed to the US National Fire Alarm Code, NFPA 72." In actuality, "there appears to be no requirement in ...
New codes and standards introduced around 2010, especially the new UL Standard 2572, the US Department of Defense's UFC 4-021-01 Design and O&M Mass Notification Systems, and NFPA 72 2010 edition Chapter 24, have led fire alarm system manufacturers to expand their systems voice evacuation capabilities to support new requirements for mass ...
From NFPA 72, 2002 Edition: “7.4.2.1* To ensure that audible public mode signals are clearly heard, unless otherwise permitted by 7.4.2.2 through 7.4.2.5, they shall have a sound level at least 15 dB above the average ambient sound level or 5 dB above the maximum sound level having a duration of at least 60 seconds, whichever is greater ...