When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Induction generator - Wikipedia

    en.wikipedia.org/wiki/Induction_generator

    An induction generator produces electrical power when its rotor is turned faster than the synchronous speed. For a four-pole motor (two pairs of poles on stator) powered by a 60 Hz source, the synchronous speed is 1800 rotations per minute (rpm) and 1500 RPM powered at 50 Hz. The motor always turns slightly slower than the synchronous speed.

  3. Motor constants - Wikipedia

    en.wikipedia.org/wiki/Motor_constants

    The rating of a brushless motor is the ratio of the motor's unloaded rotational speed (measured in RPM) to the peak (not RMS) voltage on the wires connected to the coils (the back EMF). For example, an unloaded motor of K v {\displaystyle K_{\text{v}}} = 5,700 rpm/V supplied with 11.1 V will run at a nominal speed of 63,270 rpm (= 5,700 rpm/V ...

  4. Engine–generator - Wikipedia

    en.wikipedia.org/wiki/Engine–generator

    An engine–generator is the combination of an electrical generator and an engine (prime mover) mounted together to form a single piece of equipment. This combination is also called an engine–generator set or a gen-set. In many contexts, the engine is taken for granted and the combined unit is simply called a generator. An engine–generator ...

  5. Constant speed drive - Wikipedia

    en.wikipedia.org/wiki/Constant_Speed_Drive

    Constant speed drive for Boeing 727, made by Sundstrand Corporation. A constant speed drive (CSD) also known as a constant speed generator, is a type of transmission that takes an input shaft rotating at a wide range of speeds, delivering this power to an output shaft that rotates at a constant speed, despite the varying input.

  6. Motor–generator - Wikipedia

    en.wikipedia.org/wiki/Motorgenerator

    As an example, a 250 kVA motorgenerator operating at 300 ampere of full load current will require 1550 ampere of in-rush current during a re-closure after 5 seconds. This example used a fixed mounted flywheel sized to result in a 1 ⁄ 2 Hz per second slew rate. The motorgenerator was a vertical type two-bearing machine with oil-bath ...

  7. Doubly fed electric machine - Wikipedia

    en.wikipedia.org/wiki/Doubly_fed_electric_machine

    The drawback of the Krämer drive is that the machines need to be overdimensioned in order to cope with the extra circulating power. This drawback was corrected in the Scherbius drive where the slip power is fed back to the AC grid by motor generator sets. [8] [9] The rotating machinery used for the rotor supply was heavy and expensive.

  8. Campbell diagram - Wikipedia

    en.wikipedia.org/wiki/Campbell_diagram

    Analysis shows that there are well-damped critical speed at lower speed range. Another critical speed at mode 4 is observed at 7810 rpm (130 Hz) in dangerous vicinity of nominal shaft speed, but it has 30% damping - enough to safely ignore it. Analytically computed values of eigenfrequencies as a function of the shaft's rotation speed.

  9. Overspeed - Wikipedia

    en.wikipedia.org/wiki/Overspeed

    Hydraulic governors use the centrifugal force but drive a medium to accomplish the same task. [4] The overspeed governor is implemented on most marine diesel engines. [ 4 ] The governor is a safety measure that acts when the engine is approaching overspeed and will trip the engine off if the regulator governor fails. [ 4 ]

  1. Related searches critical range of rpm for motor driven generator in different countries

    engine generator rating chartconstant speed drive generator
    engine generator ratingsdiesel engine generators