When.com Web Search

  1. Ad

    related to: test the concentration of glucose in water based method pdf file system

Search results

  1. Results From The WOW.Com Content Network
  2. Glucose clamp technique - Wikipedia

    en.wikipedia.org/wiki/Glucose_clamp_technique

    Hyperglycemic clamp technique: The plasma glucose concentration is acutely raised to 125 mg/dl above basal levels by a continuous infusion of glucose. This hyperglycemic plateau is maintained by adjustment of a variable glucose infusion, based on the rate of insulin secretion and glucose metabolism. Because the plasma glucose concentration is ...

  3. Blood glucose monitoring - Wikipedia

    en.wikipedia.org/wiki/Blood_glucose_monitoring

    Blood glucose monitoring is the use of a glucose meter for testing the concentration of glucose in the blood . Particularly important in diabetes management , a blood glucose test is typically performed by piercing the skin (typically, via fingerstick ) to draw blood, then applying the blood to a chemically active disposable 'test-strip'.

  4. Blood sugar level - Wikipedia

    en.wikipedia.org/wiki/Blood_sugar_level

    But following meals, capillary and arterial blood glucose levels can be significantly higher than venous levels. Although these differences vary widely, one study found that following the consumption of 50 grams of glucose, "the mean capillary blood glucose concentration is higher than the mean venous blood glucose concentration by 35%." [33] [34]

  5. Automated analyser - Wikipedia

    en.wikipedia.org/wiki/Automated_analyser

    The design based on separating a continuously flowing stream with air bubbles largely reduced slow, clumsy, and error-prone manual methods of analysis. The types of tests include enzyme levels (such as many of the liver function tests ), ion levels (e.g. sodium and potassium , and other tell-tale chemicals (such as glucose , serum albumin , or ...

  6. Glucose meter - Wikipedia

    en.wikipedia.org/wiki/Glucose_meter

    Besides glucose oxidase, the test kit contains a benzidine derivative, which is oxidized to a blue polymer by the hydrogen peroxide formed in the oxidation reaction. The disadvantage of this method was that the test strip had to be developed after a precise interval (the blood had to be washed away), and the meter needed to be calibrated ...

  7. Noninvasive glucose monitor - Wikipedia

    en.wikipedia.org/wiki/Noninvasive_glucose_monitor

    Noninvasive glucose monitoring (NIGM), called Noninvasive continuous glucose monitoring when used as a CGM technique, is the measurement of blood glucose levels, required by people with diabetes to prevent both chronic and acute complications from the disease, without drawing blood, puncturing the skin, or causing pain or trauma. The search for ...

  8. Intravenous sugar solution - Wikipedia

    en.wikipedia.org/wiki/Intravenous_sugar_solution

    D50 – 50% dextrose in water; The percentage is a mass concentration, so a 5% glucose/dextrose solution contains 50 g/L of glucose/dextrose (5 g per 100 ml). This usage is imprecise but widely used, as discussed at Mass concentration (chemistry) § Usage in biology. Glucose provides energy 4 kcal/gram, so a 5% glucose solution provides 0.2 kcal/ml

  9. Benedict's reagent - Wikipedia

    en.wikipedia.org/wiki/Benedict's_reagent

    Substance in water + 3 mL Benedict's solution, then boil for few minutes and allow to cool. Red, green, or yellow precipitate is obtained Reducing sugar, such as glucose, is present Substance in water + 3 mL Benedict's solution, then boil for few minutes and allow to cool. Solution remains clear or is a little blue Reducing sugar is not present