When.com Web Search

  1. Ad

    related to: pressure in crankcase system of air conditioning treatment plan

Search results

  1. Results From The WOW.Com Content Network
  2. Crankcase heater - Wikipedia

    en.wikipedia.org/wiki/Crankcase_heater

    A crankcase heater is an electrical component in a compressor in an air-conditioning system, heat pump system, or chiller system. The crankcase heater is normally on all the time, even when the unit is not running, though temperature sensors and set points may turn it off when not needed.

  3. Duct leakage testing - Wikipedia

    en.wikipedia.org/wiki/Duct_leakage_testing

    As air is delivered into the ductwork, pressure builds and forces air out of all of the openings in the various ductwork connections or through the seams and joints of the furnace or air-conditioner. The tighter the ductwork system (e.g. fewer holes), the less air is needed from the fan to create a change in the ductwork pressure.

  4. Diffuser (thermodynamics) - Wikipedia

    en.wikipedia.org/wiki/Diffuser_(thermodynamics)

    A round diffuser in an HVAC system. Diffusers are very common in heating, ventilating, and air-conditioning systems. [3] Diffusers are used in both all-air and air-water HVAC systems, as part of room air distribution subsystems, and serve several purposes: To deliver both conditioning and ventilating air

  5. Ductwork airtightness - Wikipedia

    en.wikipedia.org/wiki/Ductwork_airtightness

    The relationship between pressure and leakage air flow rate is defined by the power law model between the airflow rate and the pressure difference across the ductwork envelope as follows: q L =C L ∆p n. where: q L is the volumetric leakage airflow rate expressed in L.s −1; C L is the air leakage coefficient expressed in L.s −1.Pa −n

  6. Discharge pressure - Wikipedia

    en.wikipedia.org/wiki/Discharge_pressure

    Discharge pressure (also called high side pressure or head pressure) is the pressure generated on the output side of a gas compressor in a refrigeration or air conditioning system. The discharge pressure is affected by several factors: size and speed of the condenser fan, condition and cleanliness of the condenser coil, and the size of the ...

  7. Vapor-compression refrigeration - Wikipedia

    en.wikipedia.org/wiki/Vapor-compression...

    A representative pressure–volume diagram for a refrigeration cycle. Vapour-compression refrigeration or vapor-compression refrigeration system (VCRS), [1] in which the refrigerant undergoes phase changes, is one of the many refrigeration cycles and is the most widely used method for air conditioning of buildings and automobiles.

  8. Reciprocating compressor - Wikipedia

    en.wikipedia.org/wiki/Reciprocating_compressor

    A reciprocating compressor or piston compressor is a positive-displacement compressor that uses pistons driven by a crankshaft to deliver gases at high pressure. [ 1 ] [ 2 ] Pressures of up to 5,000 psig are commonly produced by multistage reciprocating compressors.

  9. Duct (flow) - Wikipedia

    en.wikipedia.org/wiki/Duct_(flow)

    Downstream of the air handler, the supply air trunk duct will commonly fork, providing air to many individual air outlets such as diffusers, grilles, and registers. When the system is designed with a main duct branching into many subsidiary branch ducts, fittings called take-offs allow a small portion of the flow in the main duct to be diverted ...

  1. Ad

    related to: pressure in crankcase system of air conditioning treatment plan