When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Linear sweep voltammetry - Wikipedia

    en.wikipedia.org/wiki/Linear_sweep_voltammetry

    The slope of the potential vs. time graph is called the scan rate and can range from mV/s to 1,000,000 V/s. [3] The working electrode is one of the electrodes at which the oxidation/reduction reactions occur—the processes that occur at this electrode are the ones being monitored. The auxiliary electrode (or counter electrode) is the one at ...

  3. Voltammetry - Wikipedia

    en.wikipedia.org/wiki/Voltammetry

    Linear potential sweep. Voltammetry is a category of electroanalytical methods used in analytical chemistry and various industrial processes. In voltammetry, information about an analyte is obtained by measuring the current as the potential is varied.

  4. Squarewave voltammetry - Wikipedia

    en.wikipedia.org/wiki/Squarewave_voltammetry

    As a result of having current sampling at two different instances per squarewave cycle, two current waveforms are collected - both have diagnostic value, and are therefore preserved. When viewed in isolation, the forward and reverse current waveforms mimic the appearance of a cyclic voltammogram (which corresponds to the anodic or cathodic ...

  5. Reference ranges for blood tests - Wikipedia

    en.wikipedia.org/wiki/Reference_ranges_for_blood...

    Reference ranges (reference intervals) for blood tests are sets of values used by a health professional to interpret a set of medical test results from blood samples. Reference ranges for blood tests are studied within the field of clinical chemistry (also known as "clinical biochemistry", "chemical pathology" or "pure blood chemistry"), the ...

  6. Cyclic voltammetry - Wikipedia

    en.wikipedia.org/wiki/Cyclic_voltammetry

    The solvent, electrolyte, and material composition of the working electrode will determine the potential range that can be accessed during the experiment. The electrodes are immobile and sit in unstirred solutions during cyclic voltammetry. This "still" solution method gives rise to cyclic voltammetry's characteristic diffusion-controlled peaks.

  7. Fast-scan cyclic voltammetry - Wikipedia

    en.wikipedia.org/wiki/Fast-scan_cyclic_voltammetry

    This will result in a movement of electrons in solution that will ultimately create a small alternating current (nano amps scale). [4] By subtracting the background current created by the probe from the resulting current, it is possible to generate a voltage vs. current plot that is unique to each compound. [ 5 ]

  8. Polarography - Wikipedia

    en.wikipedia.org/wiki/Polarography

    Typical amplitudes of these pulses range between 10 and 50 mV, whereas pulse duration is 20 to 50 ms. The difference between both current values is the analytical signal. This technique results in a 100 to 1000-fold improvement of the detection limit, because the capacitive component is effectively subtracted.

  9. Rotating disk electrode - Wikipedia

    en.wikipedia.org/wiki/Rotating_disk_electrode

    An RDE cannot be used to observe the behavior of the electrode reaction products, since they are continually swept away from the electrode. However, the rotating ring-disk electrode is well suited to investigate this further reactivity. The peak current in a cyclic voltammogram for an RDE is a plateau like region, governed by the Levich ...