When.com Web Search

  1. Ads

    related to: power transformer sizing calculation worksheets printable free

Search results

  1. Results From The WOW.Com Content Network
  2. Short-circuit test - Wikipedia

    en.wikipedia.org/wiki/Short-circuit_test

    A different form of short-circuit testing is done to assess the mechanical strength of the transformer windings, and their ability to withstand the high forces produced if an energized transformer experiences a short-circuit fault. Currents during such events can be several times the normal rated current.

  3. Distribution transformer - Wikipedia

    en.wikipedia.org/wiki/Distribution_transformer

    The invention of a practical, efficient transformer made AC power distribution feasible; a system using distribution transformers was demonstrated as early as 1882. [2] If mounted on a utility pole, they are called pole-mount transformers. Suppose the distribution lines are located at ground level or underground.

  4. Stacking factor - Wikipedia

    en.wikipedia.org/wiki/Stacking_factor

    Stacking factors are typically 0.95 or higher for transformer cores [4] and machine stators. [5] However, cores made from amorphous metal have a stacking factor of around 0.8, compared to 0.96 for silicon steel. [1] A related concept in transformer design is window space factor. This is defined as the ratio of the area occupied by the copper ...

  5. Mathematics of three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Mathematics_of_three-phase...

    Such arrays will evenly balance the polyphase load between the phases of the source system. For example, balanced two-phase power can be obtained from a three-phase network by using two specially constructed transformers, with taps at 50% and 86.6% of the primary voltage.

  6. High-leg delta - Wikipedia

    en.wikipedia.org/wiki/High-leg_delta

    Center-tapped delta transformer Center-tapped delta transformer voltages. High-leg delta service is supplied in one of two ways. One is by a three-phase transformer (or three single-phase transformers), having four wires coming out of the secondary, the three phases, plus a neutral connected as a center-tap on one of the windings.

  7. Symmetrical components - Wikipedia

    en.wikipedia.org/wiki/Symmetrical_components

    Set of three unbalanced phasors, and the necessary symmetrical components that sum up to the resulting plot at the bottom. In 1918 Charles Legeyt Fortescue presented a paper [4] which demonstrated that any set of N unbalanced phasors (that is, any such polyphase signal) could be expressed as the sum of N symmetrical sets of balanced phasors, for values of N that are prime.

  8. Transformer types - Wikipedia

    en.wikipedia.org/wiki/Transformer_types

    The powder core enables high-frequency operation, [7] and hence much smaller size-to-power ratio than laminated-iron transformers. Ferrite transformers are not used as power transformers at mains frequency since laminated iron cores cost less than an equivalent ferrite core.

  9. Voltage transformer - Wikipedia

    en.wikipedia.org/wiki/Voltage_transformer

    A capacitor voltage transformer (CVT), is a transformer used in power systems to step down extra high voltage signals and provide a low voltage signal to the actual VT (voltage transformer) used for operating metering/protective relays due to a lower cost than an electromagnetic PT. The circuit diagram for a simple capacitor voltage transformer