When.com Web Search

  1. Ads

    related to: standard transformer kva sizes calculator for generator parts diagram

Search results

  1. Results From The WOW.Com Content Network
  2. Pad-mounted transformer - Wikipedia

    en.wikipedia.org/wiki/Pad-mounted_transformer

    ANSI C57.12.00 – Standard General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers ANSI C57.12.22 – Standard for Transformers - Pad-Mounted, Compartmental-Type, Self-Cooled, Three-Phase Distribution Transformers with High-Voltage Bushings, 2500 kVA and Smaller: High Voltage, 34,500Grd/19,920 Volts, and Below ...

  3. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    Portable transformers that transform single-phase 240 V to this 110 V split-phase system are a common piece of construction equipment. Generator sets used for construction sites are equipped to supply it directly. However, a large farm may be given a 230–0–230 (nominal) supply.

  4. Per-unit system - Wikipedia

    en.wikipedia.org/wiki/Per-unit_system

    By choosing the base quantities in this manner, the transformer can be effectively removed from the circuit as described above. For example: Take a transformer that is rated at 10 kVA and 240/100 V. The secondary side has an impedance equal to 1∠0° Ω. The base impedance on the secondary side is equal to:

  5. Distribution transformer - Wikipedia

    en.wikipedia.org/wiki/Distribution_transformer

    Distribution transformers typically have ratings less than 200 kVA, [3] although some national standards allow units up to 5000 kVA to be described as distribution transformers. Since distribution transformers are energized 24 hours a day (even when they don't carry any load), reducing iron losses is vital in their design.

  6. Scott-T transformer - Wikipedia

    en.wikipedia.org/wiki/Scott-T_transformer

    Standard Scott Connection 3 φ to 2 φ. Assuming the desired voltage is the same on the two and three phase sides, the Scott-T transformer connection (shown right) consists of a centre-tapped 1:1 ratio main transformer, T1, and a √ 3 /2(≈86.6%) ratio teaser transformer, T2. The centre-tapped side of T1 is connected between two of the phases ...

  7. Zigzag transformer - Wikipedia

    en.wikipedia.org/wiki/Zigzag_transformer

    It is used as a grounding transformer, creating a missing neutral connection from an ungrounded 3-phase system to permit the grounding of that neutral to an earth reference point; to perform harmonic mitigation, as they can suppress triplet (3rd, 9th, 15th, 21st, etc.) harmonic currents; [2] to supply 3-phase power as an autotransformer ...

  8. Transformer types - Wikipedia

    en.wikipedia.org/wiki/Transformer_types

    A leakage transformer, also called a stray-field transformer, has a significantly higher leakage inductance than other transformers, sometimes increased by a magnetic bypass or shunt in its core between primary and secondary, which is sometimes adjustable with a set screw. This provides a transformer with an inherent current limitation due to ...

  9. Single-line diagram - Wikipedia

    en.wikipedia.org/wiki/Single-line_diagram

    A typical one-line diagram with annotated power flows. Red boxes represent circuit breakers, grey lines represent three-phase bus and interconnecting conductors, the orange circle represents an electric generator, the green spiral is an inductor, and the three overlapping blue circles represent a double-wound transformer with a tertiary winding.