When.com Web Search

  1. Ads

    related to: sporlan solenoid valve sizing chart

Search results

  1. Results From The WOW.Com Content Network
  2. Flow coefficient - Wikipedia

    en.wikipedia.org/wiki/Flow_coefficient

    A simplified version of the definition is: The k v factor of a valve indicates "The water flow in m 3 /h, at a pressure drop across the valve of 1 kgf/cm 2 when the valve is completely open. The complete definition also says that the flow medium must have a density of 1000 kg/m 3 and a kinematic viscosity of 10 −6 m 2 /s , e.g. water.

  3. Solenoid valve - Wikipedia

    en.wikipedia.org/wiki/Solenoid_valve

    Solenoid valves. A solenoid valve is an electromechanically operated valve.. Solenoid valves differ in the characteristics of the electric current they use, the strength of the magnetic field they generate, the mechanism they use to regulate the fluid, and the type and characteristics of fluid they control.

  4. Propane, butane, and LPG container valve connections

    en.wikipedia.org/wiki/Propane,_butane,_and_LPG...

    A DIN standard for gas cylinder valves for test pressures up to 300 bar (4,400 psi). EN 15202 [9] A European standard for LPG equipment and accessories, specifying LPG cylinder valve connections. [10] EN 417: European norm specification concerning non-refillable metallic cartridges for liquefied petroleum gases.

  5. List of valves - Wikipedia

    en.wikipedia.org/wiki/List_of_valves

    Choke valve, Butterfly valve used to limit air intake in internal combustion engine. (Not to be confused with choke valves used in industrial flow control, above.) Clapper valve: a type of check valve used in the Siamese fire appliance to allow only one hose to be connected instead of two (the clapper valve blocks the other side from leaking out)

  6. Thermal expansion valve - Wikipedia

    en.wikipedia.org/wiki/Thermal_expansion_valve

    A thermal expansion valve or thermostatic expansion valve (often abbreviated as TEV, TXV, or TX valve) is a component in vapor-compression refrigeration and air conditioning systems that controls the amount of refrigerant released into the evaporator and is intended to regulate the superheat of the refrigerant that flows out of the evaporator ...

  7. Automatic balancing valve - Wikipedia

    en.wikipedia.org/wiki/Automatic_balancing_valve

    Traditional control valves make it inevitable. As we size a control valve, the K v calculated almost certainly will not match the K v of the nearest appropriate valve. For example, a K v calculation of 4.5 m 3 /h would most likely lead to the selection of a valve with a K v = 6.3 m 3 /h. This means the valve is capable of delivering 40% more ...