Treatment includes several procedures aiming at removing foreign bodies from the airways. Most modern protocols, including those of the American Heart Association, American Red Cross and the European Resuscitation Council, [4] recommend several stages, designed to apply more pressure increasingly. Basic treatment includes several procedures ...
Hold the suction catheter (wide-bore, rigid) in a clenched-fisted right hand, with the distal end of the catheter pointing caudad and posterior, to enable manipulation of the tongue and mandible as required. The curve of the rigid suction catheter should mirror the curve of the structures of the upper airway: 3.
The most widely used route is orotracheal, in which an endotracheal tube is passed through the mouth and vocal apparatus into the trachea. In a nasotracheal procedure, an endotracheal tube is passed through the nose and vocal apparatus into the trachea. Alternatives to standard endotracheal tubes include laryngeal tube and combitube. [citation ...
A cuffed endotracheal tube, constructed of polyvinyl chloride A Carlens double-lumen endotracheal tube, used for thoracic surgical operations such as VATS lobectomy. A tracheal tube is a catheter that is inserted into the trachea for the primary purpose of establishing and maintaining a patent (open and unobstructed) airway.
An endotracheal tube is a specific type of tracheal tube that is nearly always inserted through the mouth (orotracheal) or nose (nasotracheal). A tracheostomy tube is another type of tracheal tube; this 50–75-millimetre-long (2.0–3.0 in) curved metal or plastic tube may be inserted into a tracheostomy stoma (following a tracheotomy ) to ...
Airway adjuncts may be required. If the airway is blocked (e.g., by blood or vomit), the fluid must be cleaned out of the patient's mouth by the help of suctioning instruments. In the case of obstruction, pass an endotracheal tube. [citation needed]
A tracheostomy tube or endotracheal tube with a 6 or 7 mm internal diameter is then inserted, the cuff is inflated, and the tube is secured. The person performing the procedure might utilize a bougie device, a semi-rigid, straight piece of plastic with a 25-mm tip at a 30-degree angle, to provide rigidity to the tube and assist with guiding its ...
A double lumen endotracheal tube is used to keep one lung breathing while the other is being washed. The lung to be washed is filled with fluid by gravity, then drained. Drainage can be done by suction [2] or gravity. [10] Some versions add a shaking step between the filling and draining to help with the washing. [2]