Ads
related to: supplemental current limiting devices
Search results
Results From The WOW.Com Content Network
An inrush current limiter is a device or devices combination used to limit inrush current. Passive resistive components such as resistors (with power dissipation drawback), or negative temperature coefficient (NTC) thermistors are simple options while the positive one (PTC) is used to limit max current afterward as the circuit has been operating (with cool-down time drawback on both).
NTC thermistors can be used as inrush-current limiting devices in power supply circuits when added in series with the circuit being protected. They present a higher resistance initially, which prevents large currents from flowing at turn-on. As current continues to flow, NTC thermistors heat up, allowing higher current flow during normal operation.
It is known as a current-limiting diode (CLD) or current-regulating diode (CRD). Internal structure. It consists of an n-channel JFET with the gate shorted to the source, which functions like a two-terminal current limiter (analogous to a voltage-limiting Zener diode). It allows a current through it to rise to a certain value, but not higher.
In addition to the current limiting function, the device serves to filter out spikes of current [7] and may also reduce injection of harmonic currents into the power supply. The most common type is designed for three-phase electric power , in which three isolated inductors are each wired in series with one of the three line phases. [ 8 ]
An electrical ballast is a device placed in series with a load to limit the amount of current in an electrical circuit. A familiar and widely used example is the inductive ballast used in fluorescent lamps to limit the current through the tube, which would otherwise rise to a destructive level due to the negative differential resistance of the ...
Category for standard protection devices fitted to commercial or domestic electrical supplies, to monitor leakages to earth, which cause a subsequent over-current Pages in category "Over-current protection devices"
A fault current limiter (FCL), also known as fault current controller (FCC), [1] is a device which limits the prospective fault current when a fault occurs (e.g. in a power transmission network) without complete disconnection. The term includes superconducting, solid-state and inductive devices. [2]
The device operates by shunting excess current when the induced voltage exceeds the avalanche breakdown potential. It is a clamping device, suppressing all overvoltages above its breakdown voltage. It automatically resets when the overvoltage goes away, but absorbs much more of the transient energy internally than a similarly rated crowbar device.