English: This psychrometric chart represents the acceptable combination of air temperature and humidity values, according to the PMV/PPD method in the ASHRAE 55-2010 Standard. The comfort zone in blue represents the 90% of acceptability, which means the conditions between -0.5 and +0.5 PMV, or PPD < 10%.
A psychrometric chart is a graph of the thermodynamic parameters of moist air at a constant pressure, often equated to an elevation relative to sea level. The ASHRAE-style psychrometric chart, shown here, was pioneered by Willis Carrier in 1904. [10] It depicts these parameters and is thus a graphical equation of state. The parameters are:
Operative temperature is used in heat transfer and thermal comfort analysis in transportation and buildings. [10] Most psychrometric charts used in HVAC design only show the dry bulb temperature on the x-axis(abscissa), however, it is the operative temperature which is specified on the x-axis of the psychrometric chart illustrated in ANSI/ASHRAE Standard 55 – Thermal Environmental Conditions ...
The first group of metric units are those that are at present defined as units within the International System of Units (SI). In its most restrictive interpretation, this is what may be meant when the term metric unit is used. The unit one (1) is the unit of a quantity of dimension one. It is the neutral element of any system of units. [2]
The SI system after 1983, but before the 2019 revision: Dependence of base unit definitions on other base units (for example, the metre is defined as the distance travelled by light in a specific fraction of a second), with the constants of nature and artefacts used to define them (such as the mass of the IPK for the kilogram).
The representation is made on a temperature-relative humidity, instead of a standard psychrometric chart. The comfort zone in blue represents the 90% of acceptability, which means the conditions between -0.5 and +0.5 PMV, or PPD < 10%.
The dry-bulb temperature (DBT) is the temperature of air measured by a thermometer freely exposed to the air, but shielded from radiation. [1] The dry-bulb temperature is the temperature that is usually thought of as air temperature, and it is the true thermodynamic temperature.
The current international standard for the metric system is the International System of Units (Système international d'unités or SI). It is a system in which all units can be expressed in terms of seven units. The units that serve as the SI base units are the metre, kilogram, second, ampere, kelvin, mole, and candela.