A thermal mass flow meter has a turndown ratio of 1000:1. An orifice plate meter has a practical turndown ratio of 3:1. A turbine meter has a turndown ratio of 10:1. Rotary positive displacement meters have a turndown ratio of between 10:1 and 80:1, depending on the manufacturer and the application.
Boilers have a turndown ratio which is the ratio of the maximum power output to the minimum power output for which combustion can be maintained. If the control system determines that the demand falls below the minimum power output, then the boiler will cycle off until the water temperature has fallen, and then will reignite and heat the water.
Energy conversion efficiency (η) is the ratio between the useful output of an energy conversion machine and the input, in energy terms. The input, as well as the useful output may be chemical , electric power , mechanical work , light (radiation), or heat .
The coefficient of performance or COP (sometimes CP or CoP) of a heat pump, refrigerator or air conditioning system is a ratio of useful heating or cooling provided to work (energy) required. [ 1 ] [ 2 ] Higher COPs equate to higher efficiency, lower energy (power) consumption and thus lower operating costs.
For a heat engine, thermal efficiency is the ratio of the net work output to the heat input; in the case of a heat pump, thermal efficiency (known as the coefficient of performance or COP) is the ratio of net heat output (for heating), or the net heat removed (for cooling) to the energy input (external work). The efficiency of a heat engine is ...
These classifications are determined based on the boiler's power output, energy performance, model type, energy consumption, and energy efficiency. [2] In a residential setting, an electric boiler is often used as a backup to a house's heating system. During the colder months, heating and hot water is used more frequently.
But for an instantaneous fuel consumption rate, the thermal efficiency may be better. The theoretical limit for a conventional furnace's instantaneous efficiency is 100%, whereas a heat pump used for building heating may exceed 100%. For example, a COP of 1.5 is equivalent to 150%. Heat pumps are readily available for electric and gas sources. [3]
Heating seasonal performance factor (HSPF) is a term used in the heating and cooling industry. HSPF is specifically used to measure the efficiency of air source heat pumps. HSPF is defined as the ratio of heat output (measured in BTUs) over the heating season to electricity used (measured in watt-hours). [1] [2] It therefore has units of BTU ...