When.com Web Search

  1. Ads

    related to: how to calculate impact load factor of water pressure gauge

Search results

  1. Results From The WOW.Com Content Network
  2. Water flow test - Wikipedia

    en.wikipedia.org/wiki/Water_flow_test

    First, a static pressure gauge is attached to the test hydrant and the static water pressure is measured at the test hydrant. Second, the flow hydrant opened to allow water to flow in a fully open condition. Simultaneously the pitot tube pressure is recorded from the flow hydrant while the residual pressure is measured from the test hydrant.

  3. Gauge factor - Wikipedia

    en.wikipedia.org/wiki/Gauge_factor

    The definition of the gauge factor does not rely on temperature, however the gauge factor only relates resistance to strain if there are no temperature effects. In practice, where changes in temperature or temperature gradients exist, the equation to derive resistance will have a temperature term. The total effect is:

  4. Deadweight tester - Wikipedia

    en.wikipedia.org/wiki/Deadweight_tester

    A dead weight tester (DWT) is a calibration standard method that uses a piston cylinder on which a load is placed to make an equilibrium with an applied pressure underneath the piston. Deadweight testers are secondary standards which means that the pressure measured by a deadweight tester is defined through other quantities: length, mass and ...

  5. Inch of water - Wikipedia

    en.wikipedia.org/wiki/Inch_of_water

    It is defined as the pressure exerted by a column of water of 1 inch in height at defined conditions. At a temperature of 4 °C (39.2 °F) pure water has its highest density (1000 kg/m 3). At that temperature and assuming the standard acceleration of gravity, 1 inAq is approximately 249.082 pascals (0.0361263 psi). [2]

  6. Hazen–Williams equation - Wikipedia

    en.wikipedia.org/wiki/Hazen–Williams_equation

    The Hazen–Williams equation is an empirical relationship that relates the flow of water in a pipe with the physical properties of the pipe and the pressure drop caused by friction. It is used in the design of water pipe systems [ 1 ] such as fire sprinkler systems , [ 2 ] water supply networks , and irrigation systems.

  7. Flow coefficient - Wikipedia

    en.wikipedia.org/wiki/Flow_coefficient

    A simplified version of the definition is: The k v factor of a valve indicates "The water flow in m 3 /h, at a pressure drop across the valve of 1 kgf/cm 2 when the valve is completely open. The complete definition also says that the flow medium must have a density of 1000 kg/m 3 and a kinematic viscosity of 10 −6 m 2 /s, e.g. water. [clarify]

  8. Pressure measurement - Wikipedia

    en.wikipedia.org/wiki/Pressure_measurement

    Example of the widely used Bourdon pressure gauge Checking tire pressure with a spring and piston tire-pressure gauge. Pressure measurement is the measurement of an applied force by a fluid (liquid or gas) on a surface. Pressure is typically measured in units of force per unit of surface area.

  9. Hydrostatic test - Wikipedia

    en.wikipedia.org/wiki/Hydrostatic_test

    The vessel is filled with a nearly incompressible liquid – usually water or oil – pressurised to test pressure, and examined for leaks or permanent changes in shape. Red or fluorescent dyes may be added to the water to make leaks easier to see. The test pressure is always considerably higher than the operating pressure to give a factor of ...