When.com Web Search

  1. Ads

    related to: 60 amp unfused disconnect cable with 2

Search results

  1. Results From The WOW.Com Content Network
  2. Ring circuit - Wikipedia

    en.wikipedia.org/wiki/Ring_circuit

    The IET Wiring Regulations permit an unlimited number of 13A socket outlets (at any point unfused single or double, or any number fused) to be installed on a ring circuit, provided that the floor area served does not exceed 100 m 2. In practice, most small and medium houses have one ring circuit per storey, with larger premises having more.

  3. IEC 60309 - Wikipedia

    en.wikipedia.org/wiki/IEC_60309

    The cable connectors and sockets are keyed and colour-coded, according to the voltage range and frequency used; common colours for 50–60 Hz AC power are yellow for 100–130 volts, blue for 200–250 volts, and red for 380–480 volts.

  4. AC power plugs and sockets: British and related types

    en.wikipedia.org/wiki/AC_power_plugs_and_sockets:...

    In the United Kingdom and in Ireland, this system is usually referred to simply as a "13 amp plug" or a "13 amp socket". BS 546 , Two-pole and earthing-pin plugs, socket-outlets and socket-outlet adaptors for AC (50–60 Hz) circuits up to 250 V is an older British Standard for three-pin AC power plugs and sockets .

  5. Electrical wiring - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring

    The first rubber-insulated cables for US building wiring were introduced in 1922 with US patent 1458803, Burley, Harry & Rooney, Henry, "Insulated electric wire", issued 1923-06-12, assigned to Boston Insulated Wire and Cable . These were two or more solid copper electrical wires with rubber insulation, plus woven cotton cloth over each ...

  6. Electrical wiring in the United Kingdom - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_the...

    If the load is evenly split across the two directions, the current in each direction is half of the total, allowing the use of wire with half the current-carrying capacity. In practice, it is impossible to ensure the load does split evenly, so regulations require a thicker wire, of at least 2/3 the current capacity of the fuse or circuit breaker.

  7. powerCon - Wikipedia

    en.wikipedia.org/wiki/PowerCon

    It comes in two deliberately incompatible variants to prevent people connecting two mains supplies together. The type A is blue and used for power sources (power flows out of a blue-ended cable, into a chassis socket). The type B is grey and used for power drains (power flows from a chassis socket into a grey-ended cable). Couplers are ...