Ad
related to: vapor pressure script calculator freeaqualab.com has been visited by 10K+ users in the past month
- Moisture Content Analyzer
Accurate moisture measurement
Critical control and quality
- Food Safety in Production
Advanced food quality metrics
Trusted by top food brands
- Moisture Content Analyzer
Search results
Results From The WOW.Com Content Network
The boiling point of water is the temperature at which the saturated vapor pressure equals the ambient pressure. Water supercooled below its normal freezing point has a higher vapor pressure than that of ice at the same temperature and is, thus, unstable. Calculations of the (saturation) vapor pressure of water are commonly used in meteorology.
where temperature T is in degrees Celsius (°C) and saturation vapor pressure P is in kilopascals (kPa). According to Monteith and Unsworth, "Values of saturation vapour pressure from Tetens' formula are within 1 Pa of exact values up to 35 °C." Murray (1967) provides Tetens' equation for temperatures below 0 °C: [3]
This is illustrated in the vapor pressure chart (see right) that shows graphs of the vapor pressures versus temperatures for a variety of liquids. [7] At the normal boiling point of a liquid, the vapor pressure is equal to the standard atmospheric pressure defined as 1 atmosphere, [1] 760 Torr, 101.325 kPa, or 14.69595 psi.
The correct result would be P = 101.325 kPa, the normal (atmospheric) pressure. The deviation is −1.63 kPa or −1.61 %. The deviation is −1.63 kPa or −1.61 %. It is important to use the same absolute units for T and T c as well as for P and P c .
e * is the saturation water vapor pressure T is the absolute air temperature in kelvins T st is the steam-point (i.e. boiling point at 1 atm.) temperature (373.15 K) e * st is e * at the steam-point pressure (1 atm = 1013.25 hPa) Similarly, the correlation for the saturation water vapor pressure over ice is:
Values are given in terms of temperature necessary to reach the specified pressure. Valid results within the quoted ranges from most equations are included in the table for comparison. A conversion factor is included into the original first coefficients of the equations to provide the pressure in pascals (CR2: 5.006, SMI: -0.875).
Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!
P s (T) is the saturation vapor pressure in hPa; exp(x) is the exponential function; T is the air temperature in degrees Celsius; Buck (1981) also lists enhancement factors for a temperature range of −80 to 50 °C (−112 to 122 °F) at pressures of 1,000 mb, 500 mb, and 250 mb. These coefficients are listed in the table below.