When.com Web Search

  1. Ad

    related to: hydronics 2 pipe system diagram

Search results

  1. Results From The WOW.Com Content Network
  2. Hydronics - Wikipedia

    en.wikipedia.org/wiki/Hydronics

    The two-pipe reverse return configuration which is sometimes called 'the three-pipe system' is different from the two-pipe system in the way that water returns to the boiler. In a two-pipe system, once the water has left the first radiator, it returns to the boiler to be reheated, and so with the second and third etc.

  3. Hydrostatic loop - Wikipedia

    en.wikipedia.org/wiki/Hydrostatic_loop

    A hydrostatic loop, though not often used in plumbing practice, is an arrangement of pipes formed into a vertical loop to prevent backflow of water within the plumbing potable water system. Since a siphon has a maximum height that it can work (about 33 feet), a hydrostatic loop is built higher than 33 feet. There are several ways to prevent ...

  4. Piping and instrumentation diagram - Wikipedia

    en.wikipedia.org/wiki/Piping_and_instrumentation...

    Piping and instrumentation diagram of pump with storage tank. Symbols according to EN ISO 10628 and EN 62424. A more complex example of a P&ID. A piping and instrumentation diagram (P&ID) is defined as follows: A diagram which shows the interconnection of process equipment and the instrumentation used to control the process.

  5. Hydronic balancing - Wikipedia

    en.wikipedia.org/wiki/Hydronic_balancing

    Hydronic balancing, also called hydraulic balancing, is the process of optimizing the distribution of water in a building's hydronic heating or cooling system by equalizing the system pressure. In a balanced system every radiator is set to receive the proper amount of fluid in order to provide the intended indoor climate at optimum energy ...

  6. Flow distribution in manifolds - Wikipedia

    en.wikipedia.org/wiki/Flow_distribution_in_manifolds

    Thus the flow rate of the straight pipe is greater than that of the vertical one. Furthermore, because the lower energy fluid in the boundary layer branches through the channels the higher energy fluid in the pipe centre remains in the pipe as shown in Fig. 4. Fig. 4. Velocity profile along a manifold

  7. Fan coil unit - Wikipedia

    en.wikipedia.org/wiki/Fan_coil_unit

    Hydronic fan coil units can be generally divided into two types: Two-pipe fan coil units or four-pipe fan coil units. Two-pipe fan coil units have one supply and one return pipe. The supply pipe supplies either cold or hot water to the unit depending on the time of year. Four-pipe fan coil units have two supply pipes and two return pipes.

  8. Zone valve - Wikipedia

    en.wikipedia.org/wiki/Zone_valve

    A zone valve is a specific type of valve used to control the flow of water or steam in a hydronic heating or cooling system.. In the interest of improving efficiency and occupant comfort, such systems are commonly divided up into multiple zones. [1]

  9. Dual piping - Wikipedia

    en.wikipedia.org/wiki/Dual_piping

    Dual piping is a system of plumbing installations used to supply both potable and reclaimed water to a home or business. Under this system, two completely separate water piping systems are used to deliver water to the user.