Ad
related to: radiation counts per minute to dpm 10 hours
Search results
Results From The WOW.Com Content Network
Disintegrations per minute (dpm) and disintegrations per second (dps) are measures of the activity of the source of radioactivity. The SI unit of radioactivity, the becquerel (Bq), is equivalent to one disintegration per second. This unit should not be confused with cps, which is the number of counts received by an instrument from the source.
Consider the sunburn, a deterministic effect: [4] when exposed to bright sunlight for only ten minutes [5] at a high UV Index, that is to say a high average dose rate, [6] the skin can turn red and painful. The same total amount of energy from indirect sunlight spread out over several years - a low average dose rate - would not cause a sunburn ...
[3] [4] The measurements are typically expressed in counts per minute (CPM) or disintegrations per minute (DPM). Alternatively, a solid-state, tritium-specific phosphor screen can be used together with a phosphorimager to measure and simultaneously image the radiotracer. [5]
The concentration instantly steps up to its constant value when the time reaches 30 minutes, and there is a 100 count per minute (cpm) constant background. Note: A microcurie (Ci) is a measure of the disintegration rate, or activity, of a radioactive source; it is 2.22E06 disintegrations per minute.
There are two types of detected radiation readout: counts and radiation dose. The counts display is the simplest, and shows the number of ionizing events detected, displayed either as a count rate, such as "counts per minute" or "counts per second", or as a total number of counts over a set time period (an integrated total). The counts readout ...
Background radiation level is widely used in radiological health fields as a standard for setting exposure limits. [1] Presumably, a dose of radiation which is equivalent to what a person would receive in a few days of ordinary life will not increase their rate of disease measurably.
The deterministic effects that can lead to acute radiation syndrome only occur in the case of high doses (> ~10 rad or > 0.1 Gy) and high dose rates (> ~10 rad/h or > 0.1 Gy/h). A model of deterministic risk would require different weighting factors (not yet established) than are used in the calculation of equivalent and effective dose.
Recognized effects of higher acute radiation doses are described in more detail in the article on radiation poisoning.Although the International System of Units (SI) defines the sievert (Sv) as the unit of radiation dose equivalent, chronic radiation levels and standards are still often given in units of millirems (mrem), where 1 mrem equals 1/1,000 of a rem and 1 rem equals 0.01 Sv.