When.com Web Search

  1. Ads

    related to: copper cable delay skew tool for metal studs

Search results

  1. Results From The WOW.Com Content Network
  2. Copper cable certification - Wikipedia

    en.wikipedia.org/wiki/Copper_cable_certification

    The delay skew test is used to find the difference in propagation delay between the fastest and slowest set of wire pairs. An ideal skew is between 25 and 50 nanoseconds over a 100-meter cable. The lower this skew the better; less than 25 ns is excellent, but 45 to 50 ns is marginal.

  3. Propagation delay - Wikipedia

    en.wikipedia.org/wiki/Propagation_delay

    Propagation delay is equal to d / s where d is the distance and s is the wave propagation speed. In wireless communication, s=c, i.e. the speed of light. In copper wire, the speed s generally ranges from .59c to .77c. [3] [4] This delay is the major obstacle in the development of high-speed computers and is called the interconnect bottleneck in ...

  4. Time-domain reflectometer - Wikipedia

    en.wikipedia.org/wiki/Time-domain_reflectometer

    It is only after this round-trip delay that the short can be detected by the TDR. With knowledge of the signal propagation speed in the particular cable-under-test, the distance to the short can be measured. A similar effect occurs if the far end of the cable is an open circuit (terminated into an infinite impedance).

  5. Reflections of signals on conducting lines - Wikipedia

    en.wikipedia.org/wiki/Reflections_of_signals_on...

    A time-domain reflectometer; an instrument used to locate the position of faults on lines from the time taken for a reflected wave to return from the discontinuity.. A signal travelling along an electrical transmission line will be partly, or wholly, reflected back in the opposite direction when the travelling signal encounters a discontinuity in the characteristic impedance of the line, or if ...

  6. 66 block - Wikipedia

    en.wikipedia.org/wiki/66_block

    A split-50 M-type 66 block with bridging clips attached. A 66 block is a type of punch-down block used to connect sets of wires in a telephone system. They have been manufactured in four common configurations, A, B, E and M. [a] A and B styles have the clip rows on 0.25" centers while E and M have the clip rows on 0.20" centers.

  7. IEC 60228 - Wikipedia

    en.wikipedia.org/wiki/IEC_60228

    Comparison of SWG (red), AWG (blue) and IEC 60228 (black) wire gauge sizes from 0.03 to 200 mm² to scale on a 1 mm grid – in the SVG file, hover over a size to highlight it. In engineering applications, it is often most convenient to describe a wire in terms of its cross-section area, rather than its diameter, because the cross section is directly proportional to its strength and weight ...

  8. Lineman's pliers - Wikipedia

    en.wikipedia.org/wiki/Lineman's_pliers

    Lineman's pliers are used in the electrical trade to cut, straighten, and bend wire, and also to twist wires together when making splices. Lineman's can be used to strip wire and some types of cable, although wire strippers are more commonly used for this purpose as they can strip wire more quickly without damaging the conductors themselves.

  9. Twinaxial cabling - Wikipedia

    en.wikipedia.org/wiki/Twinaxial_cabling

    Twinaxial cabling, or twinax, is a type of cable similar to coaxial cable, but with two inner conductors in a twisted pair instead of one. [3] Due to cost efficiency it is becoming common in modern (2013) very-short-range high-speed differential signaling applications.