Actual cubic feet per minute (ACFM) is a unit of volumetric flow. It is commonly used by manufacturers of blowers and compressors. [1] This is the actual gas delivery with reference to inlet conditions, whereas cubic foot per minute (CFM) is an unqualified term and should only be used in general and never accepted as a specific definition without explanation.
To further confuse the issue, a centrifugal fan is a constant CFM device or a constant volume device. This means that, provided the fan speed remains constant, a centrifugal fan will pump a constant volume of air. This is not the same as pumping a constant mass of air. Again, the fan will pump the same volume, though not mass, at any other air ...
In the most basic sense, CFM means cubic feet per minute. Sounds simple enough right? Unfortunately, air is a compressible gas. To further confuse the issue, a centrifugal fan is a constant CFM device or a constant volume device. This means that, provided the fan speed remains constant, a centrifugal fan will pump a constant volume of air.
The centrifugal fan displaces a constant volume of air in a given system regardless of air density. When a centrifugal fan is specified for a given CFM and static pressure at conditions other than standard, an air density correction factor must be applied to select the proper size fan to meet the new condition. Since 200 °F (93 °C) air weighs ...
The air column from a 3-foot-diameter (0.91 m) fan, therefore, has more than six times as much friction interface per volume of air moved as does the air column from a 20-foot-diameter (6.1 m) fan. [8] When the down column of air from an HVLS fan reaches the floor, the air turns in the horizontal direction away from the column in all directions.
It applies to a fan or other air moving device when air is used as the test gas with the following exceptions: (a) air circulating fans (ceiling fans, desk fans); (b) positive pressure ventilators; (c) compressors with inter-stage cooling; (d) positive displacement machines; (e) test procedures to be used for design, production, or field testing.