When.com Web Search

  1. Ads

    related to: gpm to pipe size calculator

Search results

  1. Results From The WOW.Com Content Network
  2. Hazen–Williams equation - Wikipedia

    en.wikipedia.org/wiki/Hazen–Williams_equation

    Hazen–Williams equation. The Hazen–Williams equation is an empirical relationship which relates the flow of water in a pipe with the physical properties of the pipe and the pressure drop caused by friction. It is used in the design of water pipe systems [1] such as fire sprinkler systems, [2] water supply networks, and irrigation systems.

  3. Fixture unit - Wikipedia

    en.wikipedia.org/wiki/Fixture_unit

    In order to determine the required size of pipe, an arbitrary unit is used for pipe sizing which takes into account the likelihood that all the fixtures will not be used at the same time. This is called "fixture unit" (FU). The relationship between gallons per minute (gpm) and fixture unit is not constant, but varies with the number of fixture ...

  4. Flow coefficient - Wikipedia

    en.wikipedia.org/wiki/Flow_coefficient

    Flow coefficient. The flow coefficient of a device is a relative measure of its efficiency at allowing fluid flow. It describes the relationship between the pressure drop across an orifice valve or other assembly and the corresponding flow rate. Mathematically the flow coefficient Cv (or flow-capacity rating of valve) can be expressed as.

  5. Darcy–Weisbach equation - Wikipedia

    en.wikipedia.org/wiki/Darcy–Weisbach_equation

    Darcy–Weisbach equation. In fluid dynamics, the Darcy–Weisbach equation is an empirical equation that relates the head loss, or pressure loss, due to friction along a given length of pipe to the average velocity of the fluid flow for an incompressible fluid. The equation is named after Henry Darcy and Julius Weisbach.

  6. Hardy Cross method - Wikipedia

    en.wikipedia.org/wiki/Hardy_Cross_method

    Hardy Cross method. The Hardy Cross method is an iterative method for determining the flow in pipe network systems where the inputs and outputs are known, but the flow inside the network is unknown. [1] The method was first published in November 1936 by its namesake, Hardy Cross, a structural engineering professor at the University of Illinois ...

  7. Nominal Pipe Size - Wikipedia

    en.wikipedia.org/wiki/Nominal_Pipe_Size

    Nominal Pipe Size (NPS) is a North American set of standard sizes for pipes used for high or low pressures and temperatures. [1] " Nominal" refers to pipe in non-specific terms and identifies the diameter of the hole with a non-dimensional number (for example – 2-inch nominal steel pipe" consists of many varieties of steel pipe with the only criterion being a 2.375-inch (60.3 mm) outside ...