When.com Web Search

  1. Ads

    related to: pressure transmitter calibration procedure

Search results

  1. Results From The WOW.Com Content Network
  2. Calibration - Wikipedia

    en.wikipedia.org/wiki/Calibration

    As an example, a manual process may be used for calibration of a pressure gauge. The procedure requires multiple steps, [12] to connect the gauge under test to a reference master gauge and an adjustable pressure source, to apply fluid pressure to both reference and test gauges at definite points over the span of the gauge, and to compare the ...

  3. Instrumentation in petrochemical industries - Wikipedia

    en.wikipedia.org/wiki/Instrumentation_in...

    A rising pressure in the vessel results in the PCV opening to feed more gas forward. If the pressure continues to rise some controllers then act to open a second PCV that feeds excess gas to the flare system. The pressure transmitter is configured to provide warning alarms (PAL and PAH) if the pressure exceeds set high and low limits.

  4. Pressure measurement - Wikipedia

    en.wikipedia.org/wiki/Pressure_measurement

    Pressure sensors can alternatively be called pressure transducers, pressure transmitters, pressure senders, pressure indicators, piezometers and manometers, among other names. Pressure is an expression of the force required to stop a fluid from expanding, and is usually stated in terms of force per unit area.

  5. Deadweight tester - Wikipedia

    en.wikipedia.org/wiki/Deadweight_tester

    A dead weight tester (DWT) is a calibration standard method that uses a piston cylinder on which a load is placed to make an equilibrium with an applied pressure underneath the piston. Deadweight testers are secondary standards which means that the pressure measured by a deadweight tester is defined through other quantities: length, mass and ...

  6. Custody transfer - Wikipedia

    en.wikipedia.org/wiki/Custody_transfer

    Calibrate the transmitter(s) frequently or infrequently. In the case of a DP flowmeter, size the primary element for a higher or lower differential pressure (higher DP's provide higher accuracy, at the expense of higher pressure loss). Select a flowmeter and pressure transmitter with faster or slower response.

  7. Pneumatic actuator - Wikipedia

    en.wikipedia.org/wiki/Pneumatic_actuator

    20 kPa means there is no pressure, 100 kPa means there is full range pressure (can be varied by the transmitters calibration points). As the pressure rises in the vessel, the output of the transmitter rises, this increase in pressure is sent to the valve, which causes the valve to stroke downward, and start closing the valve, decreasing flow ...