Electrical bonding is the practice of intentionally electrically connecting all exposed metal items not designed to carry electricity in a room or building as protection from electric shock. Bonding is also used to minimize electrical arcing between metal surfaces with electrical potential differences.
Equipment bonding conductors or equipment ground conductors (EGC) provide a low-impedance path between normally non-current-carrying metallic parts of equipment and one of the conductors of that electrical system's source. If any exposed metal part should become energized (fault), such as by a frayed or damaged insulator, it creates a short ...
The conductor that connects the exposed metallic parts of the consumer's electrical installation is called protective earth (PE; see also: Ground). The conductor that connects to the star point in a three-phase system, or that carries the return current in a single-phase system, is called neutral (N). Three variants of TN systems are distinguished:
Normal circuit currents flow only in the neutral, and the protective earth conductor bonds all equipment cases to earth to intercept any leakage current due to insulation failure. The neutral conductor is connected to earth at the building point of supply, but no common path to ground exists for circuit current and the protective conductor.
Section 54: Earthing arrangements, protective conductors and protective bonding conductors Section 55: Other equipment (Note: Some national standards provide an individual document for each chapter of this section, i.e. 551 Low-voltage generating sets, 557 Auxiliary circuits, 559 Luminaires and lighting installations)
Conductors for these protective functions of earthing and bonding are insulated with green/yellow (striped) colour coding, which is not permitted for any other conductors. Earthing connects exposed conductive parts of electrical equipment to a main earthing terminal (MET), which is connected to a "means of earthing" that somehow connects it to ...
Among TIA-607-B's list of metallic components in need of bonding are racks, enclosures, ladders, surge protectors, cable trays, routers, switches and patch panels. Following the bonding of telecom infrastructure components, the entire system must be bonded to the building's main ground, which is sometimes also referred to as a grounding ...
Bonding jumpers may be installed wherever metal parts are free to move on a hinge or bearing. This is done for electrical safety grounding, static electricity protection, and may also be useful for control of electromagnetic interference. For example, a control panel door may have a bonding jumper across the hinges so that the metal door is ...