When.com Web Search

  1. Ads

    related to: 1 hour fire barrier separation spray for fireplace screen reviews

Search results

  1. Results From The WOW.Com Content Network
  2. Firewall (construction) - Wikipedia

    en.wikipedia.org/wiki/Firewall_(construction)

    Firewall residential construction, separating the building into two separate residential units, and fire areas Example of a firewall used to inhibit the spread of a fire at an electrical substation. A firewall is a fire-resistant barrier used to prevent the spread of fire. Firewalls are built between or through buildings, structures, or ...

  3. High-voltage transformer fire barriers - Wikipedia

    en.wikipedia.org/wiki/High-voltage_transformer...

    The primary North American document that deals with outdoor high-voltage transformer fire barriers is NFPA 850. [1] NFPA 850 outlines that outdoor oil-insulated transformers should be separated from adjacent structures and from each other by firewalls, spatial separation, or other approved means for the purpose of limiting the damage and potential spread of fire from a transformer failure.

  4. Passive fire protection - Wikipedia

    en.wikipedia.org/wiki/Passive_fire_protection

    Canada de-rates closures, where, for instance a 2-hour closure is acceptable for use in a 3-hour fire separation, so long as the fire separation is not an occupancy separation or firewall. The lowered rating is then referred to as a fire protection rating, both for firestops, unless they contain plastic pipes and regular closures. Firestops

  5. Fire door - Wikipedia

    en.wikipedia.org/wiki/Fire_door

    Fire-resistance rated door, with wire mesh glass vision panel Industrial grade fire door rated to hydrocarbon curve and blast resistance Double fire door immediately after 3-hour fire test inside a 4-hour rated Durasteel wall Double fire door after 3-hour fire test in a 4-hour Durasteel wall, during successful 45PSI (3.1 bar) hose stream test leading to a UL Listing [1]

  6. Firestop - Wikipedia

    en.wikipedia.org/wiki/Firestop

    They receive a fire rating by combining materials in an arrangement specific to the item (a pipe or cable, for example) penetrating the fire-rated wall or floor and the construction arrangement of the fire-rated wall or floor. A two-hour-rated pipe-penetration firestop may consist of a layer of caulking over packed mineral wool. The arrangement ...

  7. Fire retardant - Wikipedia

    en.wikipedia.org/wiki/Fire_retardant

    A fire retardant is a substance that is used to slow down or stop the spread of fire or reduce its intensity. This is commonly accomplished by chemical reactions that reduce the flammability of fuels or delay their combustion. [1] [2] Fire retardants may also cool the fuel through physical action or endothermic chemical reactions.

  8. Fire damper - Wikipedia

    en.wikipedia.org/wiki/Fire_damper

    Air transfer fire dampers for doors are designed and tested for use in the lower part of door leaves and cannot be installed elsewhere or higher. In Europe, the fire door test EN 14600 and EN 1634-1 applies. Air transfer fire dampers in facades are vents applied in wall, eave soffit, gable or foundation. In the US, these are used to protect ...

  9. Fire retardant gel - Wikipedia

    en.wikipedia.org/wiki/Fire_retardant_gel

    [1] Fire-retardant gels can also be slurries that are composed of a combination of water, starch, and clay. [2] Used as fire retardants, they can be used for structure protection and in direct-attack applications against wildfires. [3] [4] Fire-retardant gels are short-term fire suppressants typically applied with ground equipment. [5]