When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Pile integrity test - Wikipedia

    en.wikipedia.org/wiki/Pile_integrity_test

    Pile integrity testing using low-strain tests such as the TDR (Transient Dynamic Response) method, is a rapid way of assessing the continuity and integrity of concrete piled foundations. The test measures: pile length, or depth to anomalies; pile head stiffness; pile shaft mobility, which is dependent on pile section and concrete properties

  3. Crosshole sonic logging - Wikipedia

    en.wikipedia.org/wiki/Crosshole_sonic_logging

    Crosshole sonic logging (CSL) is a method to determine the structural integrity of drilled shafts and other concrete piles. The CSL method is considered to be more accurate than sonic echo testing in the determination of structural soundness of concrete within the drilled shaft inside of the rebar cage. This method provides little indication of ...

  4. High strain dynamic testing - Wikipedia

    en.wikipedia.org/wiki/High_strain_dynamic_testing

    High strain dynamic testing is a method of testing deep foundations to obtain information about their capacity and integrity, and in some cases, to monitor their installation. It is codified by ASTM D4945-12 - Standard Test Method for High-Strain Dynamic Testing of Piles.

  5. Dynamic load testing - Wikipedia

    en.wikipedia.org/wiki/Dynamic_load_testing

    Dynamic load testing (or dynamic loading) is a method to assess a pile's bearing capacity by applying a dynamic load to the pile head (a falling mass) while recording acceleration and strain on the pile head. Dynamic load testing is a high strain dynamic test which can be applied after pile installation for concrete piles. For steel or timber ...

  6. Piling - Wikipedia

    en.wikipedia.org/wiki/Piling

    Both the diameter of the pile and the depth of the pile are highly specific to the ground conditions, loading conditions, and nature of the project. Pile depths may vary substantially across a project if the bearing layer is not level. Drilled piles can be tested using a variety of methods to verify the pile integrity during installation.

  7. Foundation integrity testing - Wikipedia

    en.wikipedia.org/wiki/Foundation_integrity_testing

    Foundation integrity testing is the non-destructive testing of piled foundations.It was first used in the late 1960s, and has been developed over time by many companies. Three organizations supply a majority of the test equipment in use: CEBTP (Centre Expérimental de Recherches et d'Etudes du Bâtiment et des Travaux Publics) in Europe; Integrity Testing in Asia and Australia: and by GRL ...

  8. Wave equation analysis - Wikipedia

    en.wikipedia.org/wiki/Wave_equation_analysis

    The method was first developed in the 1950s by E.A. Smith of the Raymond Pile Driving Company. Wave equation analysis of piles has seen many improvements since the 1950s such as including a thermodynamic diesel hammer model and residual stress. Commercial software packages (such as AllWave-PDP and GRLWEAP) are now available to perform the analysis.

  9. Ultrasonic pulse velocity test - Wikipedia

    en.wikipedia.org/wiki/Ultrasonic_pulse_velocity_test

    A procedure for ultrasonic testing is outlined in ASTM C597 - 09. [9] In India, till 2018 ultrasonic testing was conducted according to IS 13311-1992.From 2018, procedure and specification for Ultrasonic pulse velocity test is outlined in IS 516 Part 5:Non destructive testing of concrete Section 1:Ultrasonic Pulse Velocity Testing. This test ...