Ads
related to: calibration procedure for calipers near me
Search results
Results From The WOW.Com Content Network
AFMETCAL (Air Force METrology and CALibration Program Office), located in Heath, Ohio is the primary manager of metrology services for the U.S. Air Force. It retains engineering authority for all calibrations performed in the PMEL labs throughout the Air Force, and oversees the contractor managed and operated Air Force Primary Standards Lab ...
The standard for a caliper is usually a constant of 0.02 Vernier caliper scale with the normal 0.02 vernier constant, showing measurement of object at 19.44 mm to two decimal places. The use of the vernier scale is shown on a vernier caliper which measures the internal and the external diameters of an object.
The formal definition of calibration by the International Bureau of Weights and Measures (BIPM) is the following: "Operation that, under specified conditions, in a first step, establishes a relation between the quantity values with measurement uncertainties provided by measurement standards and corresponding indications with associated measurement uncertainties (of the calibrated instrument or ...
Oddleg calipers, Hermaphrodite calipers, or Oddleg Jennys, as pictured on the left, are generally used to scribe a line at a set distance from the edge of a workpiece. The bent leg is used to run along the workpiece edge while the scriber makes its mark at a predetermined distance, this ensures a line parallel to the edge.
Conical-tip ones ease measurement of center-to-center distances between hole centers. A stack of gauge blocks with external caliper-jaw accessories, all clamped together, acts as a quickly assembled custom-size go or no-go gauge. A special gauge block stone that cannot damage the surface is used to remove nicks and burrs to maintain ...
If the gauge block is known to be 0.75000 ± 0.00005 inch ("seven-fifty plus or minus fifty millionths", that is, "seven hundred fifty thou plus or minus half a tenth"), then the micrometer should measure it as 0.7500 inch. If the micrometer measures 0.7503 inch, then it is out of calibration.
A conformity assessment procedure is carried out before placing the instrument on the market, andv the instruments are verified after a given period of time in member states of the European Union. This has tended to cause scale technology to lag behind other technologies because expensive regulatory hurdles are involved in introducing new designs.
A caliper log is a well logging tool that provides a continuous measurement of the size and shape of a borehole along its depth [1] and is commonly used in hydrocarbon exploration. The measurements that are recorded can be an important indicator of wash-outs, cave ins or shale swelling in the borehole, which can affect the results of other well ...