Ad
related to: calibration procedure for calipers for sale
Search results
Results From The WOW.Com Content Network
The standard for a caliper is usually a constant of 0.02 Vernier caliper scale with the normal 0.02 vernier constant, showing measurement of object at 19.44 mm to two decimal places. The use of the vernier scale is shown on a vernier caliper which measures the internal and the external diameters of an object.
This is called a limited calibration. But if the final measurement requires 10% accuracy, then the 3% gauge never can be better than 3.3:1. Then perhaps adjusting the calibration tolerance for the gauge would be a better solution. If the calibration is performed at 100 units, the 1% standard would actually be anywhere between 99 and 101 units.
Oddleg calipers, Hermaphrodite calipers, or Oddleg Jennys, as pictured on the left, are generally used to scribe a line at a set distance from the edge of a workpiece. The bent leg is used to run along the workpiece edge while the scriber makes its mark at a predetermined distance, this ensures a line parallel to the edge.
Conical-tip ones ease measurement of center-to-center distances between hole centers. A stack of gauge blocks with external caliper-jaw accessories, all clamped together, acts as a quickly assembled custom-size go or no-go gauge. A special gauge block stone that cannot damage the surface is used to remove nicks and burrs to maintain ...
If the gauge block is known to be 0.75000 ± 0.00005 inch ("seven-fifty plus or minus fifty millionths", that is, "seven hundred fifty thou plus or minus half a tenth"), then the micrometer should measure it as 0.7500 inch. If the micrometer measures 0.7503 inch, then it is out of calibration.
Robot calibration is a process used to improve the accuracy of robots, particularly industrial robots which are highly repeatable but not accurate. Robot calibration is the process of identifying certain parameters in the kinematic structure of an industrial robot, such as the relative position of robot links.
A conformity assessment procedure is carried out before placing the instrument on the market, andv the instruments are verified after a given period of time in member states of the European Union. This has tended to cause scale technology to lag behind other technologies because expensive regulatory hurdles are involved in introducing new designs.
An episode of the television series Columbo [16] featured a "calibration converter," as it was called in the show. The killer had a large handgun collection in his office but none of them matched the .22 caliber of the bullet he used to kill the victim.