Results From The WOW.Com Content Network
Nominal Pipe Size (NPS) is a North American set of standard sizes for pipes used for high or low pressures and temperatures. [1] " Nominal" refers to pipe in non-specific terms and identifies the diameter of the hole with a non-dimensional number (for example – 2-inch nominal steel pipe" consists of many varieties of steel pipe with the only criterion being a 2.375-inch (60.3 mm) outside ...
STD is identical to Schedule 40 for NPS 1/8 to NPS 10, inclusive, and indicates .375" wall thickness for NPS 12 and larger. XS is identical to SCH 80 for NPS 1/8 to NPS 8, inclusive, and indicates .500" wall thickness for NPS 8 and larger. Different definitions exist for XXS, but it is generally thicker than schedule 160. [2]
Standard dimension ratio (SDR) is a method of rating a pipe's durability against pressure. The standard dimension ratio describes the correlation between the pipe dimension and the thickness of the pipe wall. [1] Common nominations are SDR11, SDR17, SDR26 and SDR35. Pipes with a lower SDR can withstand higher pressures.
For a fully filled duct or pipe whose cross-section is a convex regular polygon, the hydraulic diameter is equivalent to the diameter of a circle inscribed within the wetted perimeter. This can be seen as follows: The N {\displaystyle N} -sided regular polygon is a union of N {\displaystyle N} triangles, each of height D / 2 {\displaystyle D/2 ...
National Pipe Taper Fuel (NPTF, also called Dryseal American National Standard Taper Pipe Thread, defined by ASME B1.20.3) is designed to provide a more leak-free seal without the use of PTFE tape (often referred to by the popular brand name "Teflon") or another sealant compound. NPTF threads have the same basic shape but with crest and root ...
The history of copper pipe is similar. In the 1930s, the pipe was designated by its internal diameter and a 1 ⁄ 16-inch (1.6 mm) wall thickness. Consequently, a 1-inch (25 mm) copper pipe had a 1 + 1 ⁄ 8-inch (28.58 mm) outside diameter. The outside diameter was the important dimension for mating with fittings.
This specification covers seamless and welded black and hot-dipped galvanized steel pipe in NPS 1⁄8 to NPS 26 [DN 6 to DN 650] (Note 1), inclusive, with nominal wall thickness (Note 2) as given in Table X2.2 and Table X2.3.
The conversion factor k was chosen so that the values for C were the same as in the Chézy formula for the typical hydraulic slope of S=0.001. [9] The value of k is 0.001 −0.04. [10] Typical C factors used in design, which take into account some increase in roughness as pipe ages are as follows: [11]