An induction generator produces electrical power when its rotor is turned faster than the synchronous speed. For a four-pole motor (two pairs of poles on stator) powered by a 60 Hz source, the synchronous speed is 1800 rotations per minute (rpm) and 1500 RPM powered at 50 Hz. The motor always turns slightly slower than the synchronous speed.
The rating of a brushless motor is the ratio of the motor's unloaded rotational speed (measured in RPM) to the peak (not RMS) voltage on the wires connected to the coils (the back EMF). For example, an unloaded motor of K v {\displaystyle K_{\text{v}}} = 5,700 rpm/V supplied with 11.1 V will run at a nominal speed of 63,270 rpm (= 5,700 rpm/V ...
Many practical applications suggest as good practice that the maximum operating speed should not exceed 75% of the critical speed [citation needed]; however, some systems operate above the first critical speed, or supercritically. In such cases, it is important to accelerate the shaft through the first natural frequency quickly so that large ...
Constant speed drive for Boeing 727, made by Sundstrand Corporation. A constant speed drive (CSD) also known as a constant speed generator, is a type of transmission that takes an input shaft rotating at a wide range of speeds, delivering this power to an output shaft that rotates at a constant speed, despite the varying input.
The rotor of a turbo generator is a non-salient pole type usually with two poles. [5] The normal speed of a turbo generator is 1500 or 3000 rpm with four or two poles at 50 Hz (1800 or 3600 rpm with four or two poles at 60 Hz). The rotating parts of a turbo generator are subjected to high mechanical stresses because of the high operation speed.
An engine–generator is the combination of an electrical generator and an engine (prime mover) mounted together to form a single piece of equipment. This combination is also called an engine–generator set or a gen-set. In many contexts, the engine is taken for granted and the combined unit is simply called a generator. An engine–generator ...
The bearings have to be leak-tight. A hermetic seal, usually a liquid seal, is employed; a turbine oil at pressure higher than the hydrogen inside is typically used. A metal, e.g. brass, ring is pressed by springs onto the generator shaft, the oil is forced under pressure between the ring and the shaft; part of the oil flows into the hydrogen side of the generator, another part to the air side.
The machine thus starts as an induction motor until it approaches synchronous speed, when the rotor "pulls in" and locks to the stator field. [19] Reluctance motor designs have ratings that range from fractional horsepower (a few watts) to about 22 kW. Small reluctance motors have low torque, and are generally used for instrumentation ...